Alesis QuadraVerb Service Manual------
13
08/13/04
caution when examining the output of comparator (U8). Accidentally shorting pins 7, and 8 together
will instantly result in a dead ASIC. Other than there, and in the power supply, you really can't do any
harm with a scope probe, so explore.
The Curtiss VCAs (U5, and possibly U6), are current driven devices, so don't expect to see
any signals from these chips on a scope.
Be on the watch for user error. (i.e.,if a user complains that it won't load from a DataDisk,
check to be sure that "SYSEX ENABLE" is turned on.)
Remember to install ALL of the latest revisions, before returning the unit. This can help
prevent many unhappy returns.
All Trademarks are property of their respective companies.
Содержание QUADRAVERB
Страница 1: ...Alesis QuadraVerb Service Manual i 08 13 04 Alesis QuadraVerb Service Manual Revision 1 00 6 28 94 ...
Страница 16: ...Diagram 7 Alesis QuadraVerb Service Manual 10 08 13 04 ...
Страница 17: ...Diagram 8 Diagram 9 Alesis QuadraVerb Service Manual 11 08 13 04 ...
Страница 20: ...9 0 Schematics Alesis QuadraVerb Service Manual 14 08 13 04 ...
Страница 21: ...Alesis QuadraVerb Service Manual 15 08 13 04 ...
Страница 45: ...Service Manual History 6 28 94 1 00 First release Alesis QuadraVerb Service Manual 39 08 13 04 ...
Страница 46: ...NOTES Alesis QuadraVerb Service Manual 40 08 13 04 ...