Alphabot User Manual
Safety
1000004-MN-01 - Rev C
Page 31 of 77
2.2.1.10 Mode Switch
The Bot is provided with a 3-way selector forced guided switch connected to the safe SPLC
inputs.
Automatic:
The default mode is the Automatic mode. The Bot is operational within
the system.
Off:
The Bot is immobilized with brakes on.
Manual:
The Bot is disconnected from the WiFi network, e.g. does not respond to
operational commands or system E-stop. In this mode, only 1 axis can be moved
locally at a time for a period of 4 seconds maximum repeatable. Since the motor
controllers do not have a safe speed, the on-board SPLC disables the drive every 4
seconds to prohibit runaway conditions. The manual mode is generally used for
service.
When the work is done, switching the switch back to Automatic will put the Bot in a
system E-stop mode. Within the system, all door interlocks shall be satisfied in order to
reset that Bot at any reset location.