Problem
Solution
Temperature sensor
reads too high in the
day time.
Make certain that the sensor array is not too close to heat
generating sources or structures, such as buildings,
pavement, walls or air conditioning units.
Use the calibration feature to offset installation issues
related to radiant heat sources. Reference Section 10.6.
Relative pressure
does not agree with
official reporting
station
You may be viewing the absolute pressure, not the
relative pressure.
Select the relative pressure. Make sure you properly
calibrate the sensor to an official local weather station.
Reference Section 5.4.3 for details.
Rain gauge reports
rain when it is not
raining
An unstable mounting solution (sway in the mounting
pole) may result in the tipping bucket incorrectly
incrementing rainfall. Make sure you have a stable, level
mounting solution.
Data not reporting to
Wunderground.
com
1. Confirm your password or key is correct. It is
the password you registered on Wunderground.
com. Your Wunderground. com password cannot
begin with a non-alphanumeric character (a
limitation of Wundeground. com, not the
station). Example, $oewkrf is not a valid
password, but oewkrf$ is valid.
2. Confirm your station ID is correct. The station
ID is all caps, and the most common issue is
substituting an O for a 0 (or visa versa).
Example, KAZPHOEN11, not KAZPH0EN11
3. Make sure the date and time is correct on the
console. If incorrect, you may be reporting old
data, not real time data.
4. Make sure your time zone is set properly. If
incorrect, you may be reporting old data, not real
time data.