NETWORK DESCRIPTIONS 

V-Page is part of a system consisting of a Q-Sys Core, Network Router(s)/Switch(s), and the V-Page Stations 
themselves. A single physical connection handles both control and audio transport this connection can either be 
via Ethernet cables or Fiber Optics if your installation length exceed 328 ft.  

 

 

 

 

Содержание V-Page VP4X

Страница 1: ...V Page VP4X User s Guide August 31 2018 TABLE OF CONTENTS TABLE OF CONTENTS 1 INTELLIGENT DANTE AES67 PA STATION...

Страница 2: ...9 CONFIGURATION OF DIP SWITCHES 9 CONNECTORS 12 Q SYS CONFIGURATION AND PLUGIN 14 Q SYS V PAGE PLUGIN DETAILED VIEW AND EXPLANATION 15 Q SYS V PAGE PLUGIN PROPERTIES TAB 18 LINKING V PAGE STATIONS TO...

Страница 3: ...arries audio power control and monitor data between the V Page station and the Q Sys system A facility may incorporate an unlimited number of V Page stations by simply connecting them to Power Over Et...

Страница 4: ...that you re building something really cool and we want you to have access to the resources and support you need to be successful To start you ll find a wealth of information on our website This includ...

Страница 5: ...and wait 10 seconds for V Page unit to initialize If no Power Over Ethernet PoE is available refer to the VP4X Hardware section to learn about using an external power supply c Be sure to have your V...

Страница 6: ...6 August 31 2018 HARDWARE INFORMATION VP4X OVERVIEW V Page Model VP4X includes 4 Illuminated Paging Zone buttons a 5 Pin Female XLR connector and a clip holder designed for a Push to Talk microphone...

Страница 7: ...consisting of a Q Sys Core Network Router s Switch s and the V Page Stations themselves A single physical connection handles both control and audio transport this connection can either be via Ethernet...

Страница 8: ...te Audio and Control are using the same network switch Q Lan and Dante requires a different QoS configuration while the LAN Aux Network act as a generic ethernet port Always remember to keep the V Pag...

Страница 9: ...the behavior of the V Page DIP switching may perform different functions during power up and during runtime Default position for all the switches for normal operation is OFF UP if looking from the si...

Страница 10: ...IP switches and uses a default IP of 192 168 0 254 Web server serves up Firmware Update page For a detailed explanation on Updating V Page firmware see the Firmware Update section To exit Firmware Upd...

Страница 11: ...on NOTE Factory Test Mode is mainly used for troubleshooting It is NOT a requirement to program the V Page as all the parameters can be programmed while operating in the normal mode NOTE While in Test...

Страница 12: ...s provided if you decide not to use the Power Over Ethernet feature circled in red below The Power connector pinout is shown below looking from the front of the connector Polarity is also label on the...

Страница 13: ...ith the unit is the Electro Voice US600EL ETHERNET JACK A standard RJ 45 Ethernet Jack is used for the network connection and Power Over Ethernet PoE power SFP FOR OPTION FIBER CABLE A small form fact...

Страница 14: ...gured directly from within Q Sys We utilize a process called Link that makes the connection of Q Sys and V Page a very easy process We utilize the built in Q Sys paging station capabilities of the sta...

Страница 15: ...on 2 Firmware Current VP4X firmware version 3 Plugin Current Plugin version 4 Link Use this button to associate a physical station with the plugin component refer to Linking a Station section on the n...

Страница 16: ...n Q sys administrator 10 Control IP Address The IP Address of the V Page station 11 Audio IP Address The IP Address of the audio stream 12 Audio Stream The type of digital audio stream used Dante or A...

Страница 17: ...21 State LED Breakaway Mode Determines the mode of the station buttons Off Operate as a regular zone selection button Toggle When pressed the control pin Breakaway State LED will toggle states 01 10 T...

Страница 18: ...he microphone by press and hold a zone button Zone Button mode or by choosing Mic Button mode Control IP Address The IP address of the network control of the unit entered by the user or fully populate...

Страница 19: ...Switch 2 to the On then Off position This will reset the station into Factory Default Mode DANTE CONTROLLER SOFTWARE Dante Controller will allow you to see all your Dante devices within the network an...

Страница 20: ...k on your recently added AES67 Rx module an choose the stream name set by using Dante Controller At this point you should be able to listen to your message once the Push To Talk is triggered The Peak...

Страница 21: ...current IP in this mode Alternatively see Failsafe Recovery if unable to enter Firmware Update Mode remotely see troubleshooting guide at the end of this manual Once Firmware Update Mode is activated...

Страница 22: ...ll handle IP address automatically or the use of third party application like BootIP where the user can assign an IP address manually based on the MAC address of the network interface Each V Page unit...

Страница 23: ...Page is on a test bench and is not wired into the rest of the network To enter Failsafe Recovery Mode set the Dip Switch 2 to ON down power cycle the unit and return Dip Switch 2 to OFF up position Th...

Страница 24: ...including physical identify by the Dante MAC IP address Action Command Response Notes Pinging all the V Page Station IDs ID h0D V Page Station ID from all the V Pages online ID 99 is a default ID if...

Страница 25: ...lectro Voice US600EL Microphone w 5 pin XLR Connector RACK MOUNTING KITS Part Number RM VP4 Rack Mount Kit for VP4X 4RU Part Number RM VC12 Rack Mount Kit for VP12X or VC12X 8RU Part Number RM VP4VC12...

Страница 26: ...m Model VP32K 9 75 W x 7 H x 2 5 D 24 8cm x 17 8cm x 6 4cm Controls LED Indicators 4 12 VP4X VP12X Illuminated Zone Select Pushbuttons Ethernet Connector Female RJ 45 Microphone Input Balanced Dynamic...

Отзывы: