![Alcorn Mcbride V-Page VP4X Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/alcorn-mcbride/v-page-vp4x/v-page-vp4x_user-manual_2892729010.webp)
10
August 31, 2018
DIP SWITCH 1: LINK MODE
RUNTIME
–
LINK:
OFF => ON => OFF:
Activate/deactivate Link. Toggle once to activate, toggle again to deactivate. Link will also
exit on successful completion or will auto-exit after 60 seconds (default).
Link can be used in conjunction with Q-Sys to assign station ID, static IP/Port and Q-Sys feedback information to
the V-Page. In a sense, this pairs the V-Page with a specific Q-Sys Core. While Link is active, LEDs sequentially
light up, one at a time.
DIP SWITCH 2: FIRMWARE UPDATE MODE / RESET FACTORY DEFAULTS
POWER UP
–
FIRMWARE UPDATE MODE:
ON:
Enter Firmware Update mode. In this mode of operation, V-Page disregards all its settings and the rest of
the DIP switches and uses a default IP of 192.168.0.254. Web server serves up Firmware Update page. For a
detailed explanation on Updating V-Page firmware, see the Firmware Update section.
To exit Firmware Update Mode, return the switch to OFF position and perform a power cycle.
OFF:
Default state of the switch for normal operation.
NOTE: It’s advised to use AMI Terminal to invoke the firmware update. The
V-Page will enter the firmware update
mode on the last known IP instead of fixed 192.168.0.254
RUNTIME
–
LOAD FACTORY DEFAULTS (IN NORMAL OPERATION MODE ONLY):
OFF => ON => OFF:
Perform factory defaults. All LEDs will light up solid RED for a few seconds, then V-Page
will perform reset to defaults. Any stored settings will be erased from non-volatile memory and restored to their
factory defaults. This affects Dante settings as well.
NOTE: Loading Factory Defaults will erase all V-Page settings!!