Search and Scan Function

Search and Scan Function

l

 

In the Expanded Mode, in order to search for the desired frequencies, Search and Scan functions are provided.

A Dual Watch function is also provided where a specific frequency can be received alternately with a frequency

stored in channel memory.

 

l

 

The Search function has three different types.

All Search (

39)

Searches the entire band.

One Touch Search (

39)

Searches between two frequencies written to Search Band Channel Memory.

Program Search (

41)

Searches specific range.

l

 

The Scan function allows you to access all or specified channel memory addresses in sequence.  This function

has three different types.

All Channel Memory Scan (

43)

Scans all the frequencies stored in channel Memorys.

Memory Scan Memory (

44)

Scans specific channel memories .

Block Channel Memory Scan  (

45)

Scans frequencies stored in channel memories in a block. A block consists of 100 channel memory addresses.

When a signal is received, Scan/Search stops.  There are three ways to stop a Scan/Search and resume the

operation after. This method can be set separately for Scan and Search.

Pause Type

The Scan/Search stops when a signal is received.   However, after about 5 seconds, the Scan/Search resumes even

if a signal is being received.  This can be changed to a time other than 5 seconds using the Set Mode. ( 

45).

Busy Type

Scan/Search halts while a signal is being received.  If the no signal is received, the Scan/Search resumes after about
2 seconds. To indicate the unit in this Mode,  B  appears on the display and stays on.
Hold Type

The Scan/Search is held when a signal is received. In order to resume the Scan/Search, turn the Selector or press 5
key or ENT key. To indicate the unit in this Mode,  B  on the display flashes.

To Change the Search/Scan Type

Hold down FUNC key and press 0/SET key while Scan or Search is activated.

   (Illust. 26)

Search the Entire Bandwidth (All Search)

This searches the entire bandwidth.

 

Set to the FREQ Mode by pressing CLEAR PROGRAM key.

 

Hold down FUNC key and press 3 SEARCH key. (SEArCH is displayed.)

   (Illust. 27-1)

 

Press ENTkey.

 

(Search starts immediately.)

(Illust. 27-2)

 

To end, press CLEAR PROGRAM key.

NOTE:

l

 

During a search operation, by turning the Selector one click, or holding down FUNC key and press 5/ENT key,

the search is halted and the 

SEARCH

 blinks in the display.

l

 

If the FUNC key is held down and the Selector is turned, the MHz section can be changed without stopping the

search.

Содержание AE 500 H

Страница 1: ...l Do not attempt to disassemble or modify this product in any way This could lead to fire electric shock or breakdown CAUTION l Do not use this product for anything other than a receiver l When not i...

Страница 2: ...the receiver Do not hold the top of the antenna and attempt to install it Also do not turn the antenna excessively when tightening Illust 3 1 Do not hold the receiver by the antenna when carrying Ill...

Страница 3: ...ark place the light for the display can be switched on The light goes off after 5 seconds the key is released Hold down FUNC key and press 1 LAMP key Illust 11 1 Illust 11 2 To switch the lamp off hol...

Страница 4: ...Frequency Mode 1 82 500MHz WFM 2 128 800MHz AM 3 145 000MHz NFM 4 156 800MHz NFM 5 221 750MHz WFM 6 904 0125MHz NFM 7 3 925MHz AM 8 6 055MHz AM 9 9 595MHz AM To return to operative mode Expanded Mode...

Страница 5: ...ressed switches between the FREQ Mode and the Channel Memory Mode 8 SCAN Key l Enters numeric 8 l Pressing this key while the FUNC key is pressed starts the scanning operation 9 L OUT Key l Enters num...

Страница 6: ...s Memory Frequencies entered in this channel Memory are automatically skipped when a search is in progress When there is a frequency that you do not want to receive they can be entered into these Memo...

Страница 7: ...How To Erase The Frequencies Programmed into Channels Stored channel memory can be erased in following procedure Set the unit to Channel Memory Mode by pressing the 7 FREQ CH key while the FUNC key i...

Страница 8: ...the Set menu to display SwAP Illust 24 1 Select the first channel memory address by using the numeric keys The first channel Memory address is displayed on the left side of SwAP Illust 24 2 Enter the...

Страница 9: ...The Scan Search stops when a signal is received However after about 5 seconds the Scan Search resumes even if a signal is being received This can be changed to a time other than 5 seconds using the S...

Страница 10: ...ed while One Touch Search is activated the search range changes immediately corresponding to the numeric key pressed How To Change Search Band Channel Memory The frequency programmed into Search Band...

Страница 11: ...edure press CLEAR PROGRAM key Skipping a Frequency During a Search 1 Search Pass Channel Memory During a search the unit may stop at the unwanted frequencies such as noise or blank carrier These frequ...

Страница 12: ...nnel Memory Mode by pressing FUNC and 7 FREQ CH key simultaneously M appears on the display Set to the channel memory address specified by turning rotary knob or entering the channel number directly u...

Страница 13: ...o desired time The halting time in second is displayed Illust 38 2 To complete the procedure press CLEAR PROGRAM key Using Dual Watch The frequency in channel Pri 000 and one another frequency can be...

Страница 14: ...nd the frequency step for Auto Step see Frequency Frequency Step Reception Mode Table below Frequency range Frequency step Mode 0 50 0 52 MHz 1 kHz AM 0 52 1 62 MHz 9 kHz AM 1 62 29 00 MHz 5 kHz AM 29...

Страница 15: ...the Battery Save may be selected from 0 to 9 seconds Hold down FUNC key and press 0 SET Key Turn the selector to change Set menu to display OFF SA Illust 45 1 Hold down FUNC key and turn the selector...

Страница 16: ...to set Illust 49 2 To complete the setting press CLEAR PROGRAM key Reducing Receiving Sensitivity Attenuator This setting allows the receiver s sensitivity to be reduced intentionally to avoid overloa...

Страница 17: ...on Hold down FUNC key and press 0 SET key Turn the selector to change the Set menu to display OFF ud100 Illust 53 1 Hold down FUNC key and turn the selector to change display from OFF to on Illust 53...

Страница 18: ...perating voltage 2 2 3 5VDC Rated voltage 3 0VDC Applicable battery AA size manganese alkaline Current consumption In receivingApprox 125mA at AF OUT 60mW In stand by Approx 65mA At Battery save 1 sec...

Отзывы: