background image

by the POWER key. Please take out the batteries and replace them!

Adjusting the Volume

 

To increase the volume, turn the VOL knob clockwise.      

(Illust. 8)

 

To decrease the volume, turn the VOL knob counterclockwise.   (Illust. 7)

CAUTION

l

 

Set the volume to an acceptable loudness level.  Be sure to decrease the volume level before switching from

built-in speaker to earphones.

Adjusting the Squelch

When a signal is not being received, a noise is emitted. The Squelch adjustment eliminates this noise.  Also press

SQL OFF key to switch off the Squelch function temporarily.

 

Turn the SQL knob slowly in the 

+

 direction.        (Illust. 9)

 

Stop turning the knob when the noise disappears.

 

To turn Squelch off temporarily, press SQL OFF key. The squelch function turns off while SQL OFF is pressed.

(Illust. 10)

Note:

l

 

If the SQL knob is turned too far, it may reduce receiver

s sensitivity significantly.

l

 

If the signal is weak and the received sound is intermittent, continue to press SQL OFF key.

Lighting the Display

When using the receiver in a dark place, the light for the display can be switched on. The light goes off after 5

seconds the key is released.

 

 

Hold down FUNC key and press 1 LAMP key.

(Illust. 11-1, Illust 11-2)

 

To switch the lamp off, hold down FUNC key and press 1 LAMP key.

(Illust. 11-3)

Note:

Depending on the setting of the Set Mode, the lamp can be set to remain lit continuously. (

19)

Using the Key Lock

To prevent accidental operation, all keys except POWER can be locked and disabled. The rotary selector is also

disabled.

 

Press 6KEYL key while holding FUNC key.

 

(The Key mark is displayed.)

(Illust. 12-1, Illust 12-3)

 

Press 6KEYL key while holding FUNC key to release the key lock.

(Illust. 12-2)

Note:

l

 

Even in Key Lock function activated, the FUNC, POWER, SQL OFF, FUNC+1 LAMP keys are operative.

l

 

The rotary selector may be used by changing the initial setting. Refer to the later column for details. ( 24)

Resetting the Receiver to Initial State

With following procedure, the receiver is reset at PRESET mode with its original state except all channel memories.

 

Hold down FUNC key and press 0 SET key.

 

Turn the rotary selector and change the Set menu to display 

OFF rES

.  (Illust. 13-1)

 

Hold down FUNC key and turn the selector to change the display from 

OFF

 to 

on

Содержание AE 500 H

Страница 1: ...l Do not attempt to disassemble or modify this product in any way This could lead to fire electric shock or breakdown CAUTION l Do not use this product for anything other than a receiver l When not i...

Страница 2: ...the receiver Do not hold the top of the antenna and attempt to install it Also do not turn the antenna excessively when tightening Illust 3 1 Do not hold the receiver by the antenna when carrying Ill...

Страница 3: ...ark place the light for the display can be switched on The light goes off after 5 seconds the key is released Hold down FUNC key and press 1 LAMP key Illust 11 1 Illust 11 2 To switch the lamp off hol...

Страница 4: ...Frequency Mode 1 82 500MHz WFM 2 128 800MHz AM 3 145 000MHz NFM 4 156 800MHz NFM 5 221 750MHz WFM 6 904 0125MHz NFM 7 3 925MHz AM 8 6 055MHz AM 9 9 595MHz AM To return to operative mode Expanded Mode...

Страница 5: ...ressed switches between the FREQ Mode and the Channel Memory Mode 8 SCAN Key l Enters numeric 8 l Pressing this key while the FUNC key is pressed starts the scanning operation 9 L OUT Key l Enters num...

Страница 6: ...s Memory Frequencies entered in this channel Memory are automatically skipped when a search is in progress When there is a frequency that you do not want to receive they can be entered into these Memo...

Страница 7: ...How To Erase The Frequencies Programmed into Channels Stored channel memory can be erased in following procedure Set the unit to Channel Memory Mode by pressing the 7 FREQ CH key while the FUNC key i...

Страница 8: ...the Set menu to display SwAP Illust 24 1 Select the first channel memory address by using the numeric keys The first channel Memory address is displayed on the left side of SwAP Illust 24 2 Enter the...

Страница 9: ...The Scan Search stops when a signal is received However after about 5 seconds the Scan Search resumes even if a signal is being received This can be changed to a time other than 5 seconds using the S...

Страница 10: ...ed while One Touch Search is activated the search range changes immediately corresponding to the numeric key pressed How To Change Search Band Channel Memory The frequency programmed into Search Band...

Страница 11: ...edure press CLEAR PROGRAM key Skipping a Frequency During a Search 1 Search Pass Channel Memory During a search the unit may stop at the unwanted frequencies such as noise or blank carrier These frequ...

Страница 12: ...nnel Memory Mode by pressing FUNC and 7 FREQ CH key simultaneously M appears on the display Set to the channel memory address specified by turning rotary knob or entering the channel number directly u...

Страница 13: ...o desired time The halting time in second is displayed Illust 38 2 To complete the procedure press CLEAR PROGRAM key Using Dual Watch The frequency in channel Pri 000 and one another frequency can be...

Страница 14: ...nd the frequency step for Auto Step see Frequency Frequency Step Reception Mode Table below Frequency range Frequency step Mode 0 50 0 52 MHz 1 kHz AM 0 52 1 62 MHz 9 kHz AM 1 62 29 00 MHz 5 kHz AM 29...

Страница 15: ...the Battery Save may be selected from 0 to 9 seconds Hold down FUNC key and press 0 SET Key Turn the selector to change Set menu to display OFF SA Illust 45 1 Hold down FUNC key and turn the selector...

Страница 16: ...to set Illust 49 2 To complete the setting press CLEAR PROGRAM key Reducing Receiving Sensitivity Attenuator This setting allows the receiver s sensitivity to be reduced intentionally to avoid overloa...

Страница 17: ...on Hold down FUNC key and press 0 SET key Turn the selector to change the Set menu to display OFF ud100 Illust 53 1 Hold down FUNC key and turn the selector to change display from OFF to on Illust 53...

Страница 18: ...perating voltage 2 2 3 5VDC Rated voltage 3 0VDC Applicable battery AA size manganese alkaline Current consumption In receivingApprox 125mA at AF OUT 60mW In stand by Approx 65mA At Battery save 1 sec...

Отзывы: