Страница 1: ...Skimmer pools ALBISTONE G1 BENEFIT G1 PLUS Version 12 10 2020 Update 31 07 2021 L V Preparation for construction www ALBIXON com...

Страница 2: ...om 1 Contents 2 2 Surveying and Excavation 3 3 LevellingtheBottomoftheExcavationandDrainageoftheFoundationSlab 8 4 Concreting of the Foundation Slab 10 5 Notification of Readiness for Construction 11...

Страница 3: ...ut of the Pool Excavation Width and Length for the Pool The width and length of the excavation for the pool for the pool placed by a crane 500 mm on each side counted from the outer dimension of the p...

Страница 4: ...f the pool 4250 mm 6250 mm 8250 mm L2 foundation slab length 4700 mm 6700 mm 8700 mm L3 excavation length 5250 mm 7250 mm 9250 mm S pool width 3000 mm 2700 mm 3450 mm S1 outer width of the pool 3250 m...

Страница 5: ...of the roof This is due to the need to protect the shaft from rainwater If you do not want to have the shaft elevated above the final surface level adequate drainage of rainwater must be provided aro...

Страница 6: ...ewage and rainwater system on the premises This will enable the drainage pump and pool technology to be connected directly to the drainage which gives you more comfort in pool maintenance for example...

Страница 7: ...ow body placed on the pool shell This is to achieve the lowest power losses The maximum distance from the exterior contour of the pool shell is 2000 mm If the counterflow is not aligned with the axis...

Страница 8: ...age pump shaft serves as a sump for collecting groundwater and rainwater It must be provided with a submersible pump This pump must trigger automatically when the water level in the shaft rises and mu...

Страница 9: ...olisinslopingterrain or afterbeginningtheearthworks itisfoundthatit hasaclaysubsoil whichmeansahigherprobabilityofgroundwateranditsexercisingof pressureonthepoolbody werecommendthatyouhaveageologicals...

Страница 10: ...using a rebar mesh with the dimensions of 100 x 100 x 6 mm It is not necessary to reinforce the foundation slab under the technology shaft 4 Second Layer of Concrete Preparation for Final Layer Now po...

Страница 11: ...s trees Choose the type of crane to order accord ing to the weight of the pool and the reach at which the pool is to be placed With great er reach required the lifting capacity of the cranes diminishe...

Страница 12: ...on 4 Complete installation of the pool technology Installation of technology and its interconnection via pipes with the pool shell In order to interconnect the pool and the technology shaft correctly...

Страница 13: ...you check the wall perpendicularity and flatness and the overall shape of the pool and its diagonals frequently We recommend that the shell should always be braced at the points where reinforcing ele...

Страница 14: ...he diagonals of the pool shell In case of any deviation immediately stop the concreting operation and level the shell Concreting is carried out in layers keeping the height of a single layer of concre...

Страница 15: ...between the edge of the shaft wall and below the cover These measures are the responsibility of the user Pipes around the technology shaft or to the service room must be laid in a sand bed with a mini...

Страница 16: ...tslevelling This plate should be made of monolithic concrete reinforced with rebar mesh 100 x 100 x 6 mm The height of the base plate depends on the height of the type of paving that is chosen Make th...

Страница 17: ...m Thermal insulation extruded polystyrene 30 mm Draining pipe Concrete reinforced with rebar mesh Backfill with gravel grain size 8 to 16 mm Backfill with soil Concrete Gravel Raised terrain Dry bulk...

Страница 18: ...he edge Mirelon concrete paving concrete crushed aggregate edge tube permanently elastic sealant reinforcing wire slid through the edge Mirelon concrete paving concrete crushed aggregate support prism...

Страница 19: ...the values and parameters specified in the report 2 Remeasuring will be carried out by an authorised person in the construction industry the parameters specified in the report are the responsibility o...

Страница 20: ...n the report are the responsibility of the authorised person 3 Remeasuring will be made by the ALBIXON a s engineer this service will carry a charge of CZK 5 000 Submission of this duly completed and...

Страница 21: ...west passage point gates trees The type of crane or dered according to the pool weight and the reach at which the pool is to be placed Units Units Photo documentation of the preparation for the constr...

Страница 22: ...ng to the light earth strip FeZn 30x4 wire 8 mm main protective connection supply cable from the house switchboard c able for connection of filter pump and water management heat pump two cables electr...

Страница 23: ...P TO 20M IF THE DISTANCE IS LONGER THE CABLE MUST BE OVERSIZED THE SUPPLY CABLE FROM THE HOUSE SWITCHBOARD TO THE TECHNOLOGY SHAFT MUST BE PROVIDED BY THE CUSTOMER BEFORE THE ORDERED COMPONENTS ARE DE...

Страница 24: ...5 The heat exchanger must be connected to the main protective connection HOP Cables for electric heating n CYSY 5 J x 2 5 cable for 3kW heating and 6A 3 B circuit breaker in pool switchboard n CYSY 5...

Страница 25: ...circuit breaker C16 1 KM2 heat pump contactor FA3 counterflow circuit breaker C2 1 FA4 lighting transformer circuit breaker C6 1 TR1 safety transformer 230V 12V FU1 fuse insert 2A NF1 light remote con...

Страница 26: ...iltration contactor FA2 heat pump circuit breaker C16 1 FA3 lighting transformer circuit breaker C2 1 FA4 external socket breaker B16 1 TR1 safety transformer 230V 12V FU1 fuse insert 2A KT1 filtratio...

Страница 27: ...aker C16 1 FA3 counterflow circuit breaker C10 3 KM2 heat pump contactor FA4 lighting transformer circuit breaker C2 1 FA5 socket breaker salt system C6 1 TR1 safety transformer 230V 12V FU1 fuse inse...

Страница 28: ...n salt system and heat pump contactor KT1 salt system filtration and heat pump relay timer NF1 light remote control Xl 1 salt system power supply terminal X1 2 filtration motor power supply terminal D...

Страница 29: ...ALBISTONE G1 BENEFIT G1 PLUS Skimmer Pools 29 Notes...

Страница 30: ...30 ALBISTONE G1 BENEFIT G1 PLUS Skimmer Pools Notes...

Страница 31: ...ALBISTONE G1 BENEFIT G1 PLUS Skimmer Pools 31 Notes...

Страница 32: ...BIXON Call centre 477 07 07 11 www ALBIXON com The photographs used in this manual are for illustrative purposes only Typesetting and printing errors reserved Thank you for using the products by ALBIX...