POSSIBLE FINISHING WORKS FOR ALBISTONE POOLS:
POSSIBLE FINISHING WORKS FOR ALBISTONE POOLS:
20. 2. 2016
20. 2. 2016
CUSTOMER’S STATEMENT ON REMEASURING THE POOL FOUNDATION SLAB
Business case number
1234567890
Name and surname of the
Jan Novak
Address
Zbraslavska 55, Praha 5, 158 00
Pool dimensions according
to the business case
Widt
Lengt
Depth
3 000
mm
6 000
mm
1 500
mm
Excavation pit dimensions
(Minimum required values)
Pit width
Pit length
Pit depth
4 500
mm
7 500
mm
1 500
mm
Measured excavation pit dimensions
4580
mm
7620
mm
1530
mm
Customer name
and surname:
Date
and
signature:
Send the properly completed report to the address:
Frantz Kozel,
Stavbaz,
Jan Novak
mm
mm
Slab length
The slab width
Pool length:
6 000
mm
Pool width:
3 000
mm
0
-1
-1
-2
-1
-1
-2
-1
+1
-1
+1
+2
+1
-1
-1
-2
-1
0
0
-1
-1
-2
-1
-2
0
-1
+1
-1
-2
-1
0
-2
-1
7620
45
80
Failure to comply with the prescribed level of the base plate will not cause water to spill evenly over the entire perimeter of
the pool, and this cannot be the subject of a claim.
Remeasuring of the mandatory tolerance must be done by an authorised person.
Options of remeasuring and confirming the measured values:
(circle the chosen option)
1,
The customer remeasures the slab personally and takes full responsibility for the values and parameters specified in the report
2,
Remeasuring will be carried out by an authorised person in the construction industry – the parameters specified in the
report are the responsibility of the authorised person
3, Remeasuring will be made by the ALBIXON a.-s. engineer - this service will carry a charge of CZK 5,000
Submission of this duly completed and confirmed customer statement is a condition of entering into an agreement for
the handover of the workplace and starting works by ALBIXON a. s.
ALBIXON a. s. points out that in case of delay in notification of construction readiness, the delivery date specified in the
agreement will be extended accordingly.
Use an optical or laser device with a minimum measurement accuracy of +/- 1 mm / 10 m to measure the mandatory horizontality.
Flatness of the foundation slab
OK / NOT OK
*
in terms of the mandatory tol/– 2 mm in the whole area of the pool skeleton.
* cross out which doesn’t apply
Measured on:
Date,
stamp and
signature:
The date of the latest
device calibration
Type of used of the device:
Measurement/
alignment
made by:
20. 2.
2016
Parameters
and accuracy of the device:
Authorisation number:
0 – reference point of measuring
Minimum number of measurements:
+ 20 points on the per 12 inner points (all measured details must be specified in mm)
The slab must within the tolerance ± 2 mm along
the perimeter
SAMPLE
HILTI PR-2 HS
+/- 0,5 mm/10 m
CKAIT - xxxxxxx
11. 11. 2015