32
3.3.5 Voltage Inputs
Inputs 29,30,31,33,34,35 can be only configured in voltage.
Signal from: You can select the parameter that the input will measure engine,
battery, general fluid, general temperature, general pressure, switch bank or
general fluid.
Signal from
Physic Variable
Engine
Rotation Rate
Pressure
Engine Tilt
Temperature
Voltage
Fluid flow
Battery
Temperature
Voltage
Current
General Fluid
General fluid
General Temperature
General temperature
General Pressure
General Pressure
Limits high and low: these limits will be used to set an alarm.
Filter Level: please indicate if the level measurement has been made with low, medium
or high level.
Sensor Type: You have some predefined sensors. You can choose a sensor type
and make some changes.
Supply Correction:
You can activate the supply correction using a voltage input (Correction Channel)
IMPORTANT:
The supply voltage correction is used when the voltage inputs are used to measure from the
gauges (it does not matter the brand), since the voltage that is measured is referenced to the
supply voltage. Therefore, if this supply voltage (comes from the alternator or the battery) is not
stable, it produces fluctuations in the measurement. This option attempts to compensate the
measurement based on the deviation of the supply voltage from the expected nominal value.
To do this, the supply voltage must be connected to one of the voltage measurements channels
(usually the last one, Input 12 Voltage) and the expected nominal value must be set on the
configuration website.