![Albalá Ingenieros FRS3004C02 Скачать руководство пользователя страница 24](http://html.mh-extra.com/html/albala-ingenieros/frs3004c02/frs3004c02_manual_2889208024.webp)
Albalá Ingenieros | Manual
FRS3004C02
ACT_EDH_REF
0x02
0x01
N
N
Reference active picture EDH bit status
0=OK,1=Fail
ACT_EDA_REF
0x02
0x02
N
N
Reference active picture EDA bit status
0=OK,1=Fail
ACT_IDH_REF
0x02
0x04
N
N
Reference active picture IDH bit status
0=OK,1=Fail
ACT_IDA_REF
0x02
0x08
N
N
Reference active picture IDA bit status
0=OK,1=Fail
ACT_UES_REF
0x02
0x10
N
N
Reference active picture UES bit status
0=OK,1=Fail
FULL_EDH_1
0x03
0x01
N
N
Full field EDH bit status (Section 1)
0=OK,1=Fail
FULL_EDA_1
0x03
0x02
N
N
Full field EDA bit status (Section 1)
0=OK,1=Fail
FULL_IDH_1
0x03
0x04
N
N
Full field IDH bit status (Section 1)
0=OK,1=Fail
FULL_IDA_1
0x03
0x08
N
N
Full field IDA bit status (Section 1)
0=OK,1=Fail
FULL_UES_1
0x03
0x10
N
N
Full field UES bit status (Section 1)
0=OK,1=Fail
EDH_PCK_ERR_1
0x03
0x20
N
N
Valid EDH packet status (Section 1)
0=OK,1=Fail
EDH_PRES_1
0x03
0x40
N
N
EDH packet presence (Section 1)
0=No, 1=Yes
EDH_ERROR_1
0x03
0x80
Y
N
Indicates error in SDI signal (Section 1)
0=OK,1=Fail
ACT_EDH_1
0x04
0x01
N
N
Active picture EDH bit status (Section 1)
0=OK,1=Fail
ACT_EDA_1
0x04
0x02
N
N
Active picture EDA bit status (Section 1)
0=OK,1=Fail
ACT_IDH_1
0x04
0x04
N
N
Active picture IDH bit status (Section 1)
0=OK,1=Fail
ACT_IDA_1
0x04
0x08
N
N
Active picture IDA bit status (Section 1)
0=OK,1=Fail
ACT_UES_1
0x04
0x10
N
N
Active picture UES bit status (Section 1)
0=OK,1=Fail
FULL_EDH_2
0x05
0x01
N
N
Full field EDH bit status (Section 2)
0=OK,1=Fail
FULL_EDA_2
0x05
0x02
N
N
Full field EDA bit status (Section 2)
0=OK,1=Fail
FULL_IDH_2
0x05
0x04
N
N
Full field IDH bit status (Section 2)
0=OK,1=Fail
FULL_IDA_2
0x05
0x08
N
N
Full field IDA bit status (Section 2)
0=OK,1=Fail
FULL_UES_2
0x05
0x10
N
N
Full field UES bit status (Section 2)
0=OK,1=Fail
EDH_PCK_ERR_2
0x05
0x20
N
N
Valid EDH packet status (Section 2)
0=OK,1=Fail
EDH_PRES_2
0x05
0x40
N
N
EDH packet presence (Section 2)
0=No, 1=Yes
EDH_ERROR_2
0x05
0x80
Y
N
Indicates error in SDI signal (Section 2)
0=OK,1=Fail
ACT_EDH_2
0x06
0x01
N
N
Active picture EDH bit status (Section 2)
0=OK,1=Fail
ACT_EDA_2
0x06
0x02
N
N
Active picture EDA bit status (Section 2)
0=OK,1=Fail
ACT_IDH_2
0x06
0x04
N
N
Active picture IDH bit status (Section 2)
0=OK,1=Fail
ACT_IDA_2
0x06
0x08
N
N
Active picture IDA bit status (Section 2)
0=OK,1=Fail
ACT_UES_2
0x06
0x10
N
N
Active picture UES bit status (Section 2)
0=OK,1=Fail
FULL_EDH_3
0x07
0x01
N
N
Full field EDH bit status (Section 3)
0=OK,1=Fail
FULL_EDA_3
0x07
0x02
N
N
Full field EDA bit status (Section 3)
0=OK,1=Fail
FULL_IDH_3
0x07
0x04
N
N
Full field IDH bit status (Section 3)
0=OK,1=Fail
FULL_IDA_3
0x07
0x08
N
N
Full field IDA bit status (Section 3)
0=OK,1=Fail
24
Содержание FRS3004C02
Страница 2: ...FRS3004C02 ...
Страница 4: ...FRS3004C02 ...
Страница 7: ...Albalá Ingenieros Manual FRS3004C02 1 3 Block diagram 7 ...
Страница 8: ...Albalá Ingenieros Manual FRS3004C02 FRS3004C02 8 ...
Страница 10: ...Albalá Ingenieros Manual FRS3004C02 Approximate weight 350 g 10 ...
Страница 16: ...Albalá Ingenieros Manual FRS3004C02 FRS3004C02 16 ...
Страница 26: ...Albalá Ingenieros Manual FRS3004C02 FRS3004C02 26 ...
Страница 28: ...Albalá Ingenieros Manual FRS3004C02 FRS3004C02 28 ...
Страница 30: ...Albalá Ingenieros Manual FRS3004C02 FRS3004C02 30 ...
Страница 32: ...Albalá Ingenieros S A Medea 4 28037 Madrid Spain 34 913274453 www albalaing com info albalaing com ...