5.  Measurements 

5-1 Real time measurement 

1. Turn on Power SW 

  and confirm an indication of LCD.

   

 

Display of a measuring mode 

H

Broad Leaf Tree 

and 

LLL

 

 

z

 

Turning on Power while inserting the probe to the object indicates 

LLL

  once on the display and then 

displays a measuring value in 2 to 3 seconds. 

 

2. Select a mode suitable for the measuring object by pressing a Mode Change key

G

 

(refer to 4-3 changes of measuring modes page at 5) 

 

3. Wait for reading the display until the display has become stable by inserting Electrode into the measuring 

object. 

 

4. Press a Hold

Average key 

 to display 

0.0 %

  with a sound of “Peep”. 

When probing an object, it emits “peep, peep” sounds and when releasing it,   

a “ peep” sound again with a measured valued indicated on LCD 

* 

Do not probe other object until the above sounds of 3 times has finished   

otherwise that may cause measurement errors.

 

An indicated value does not change when a measured value indicates not   

more than the measurement range. 

When a measured value indicates not less than the measurement range,   

HHH

  blinks with sounds of “ peep, peep, peep”.     

Releasing a probe displays

0.0%

 

5. Press a Hold

Average key 

  again for releasing the Hold state. 

 

Note) When stubbing a probe into a measuring object: 

Keep Hold Mode released until stubbing has been completed. Make sure of changing to Hold Mode to 

read a measured value after finishing the stubbing. 

(Stubbing during a Hold mode in process may cause measurement errors because it displays data while 

in process of stubbing.) 

     

 

 

 

 

 

 

 

Office: Jl. Radin Inten II No. 62 Duren Sawit, Jakarta 13440 - Indonesia
Workshop: Jl. Pahlawan Revolusi No. 22B, Jakarta 13430 - Indonesia
Phone: 021-8690 6777 (Hunting)

Fax: 021-8690 6777

Mobile: +62 816 1740 8925

Содержание TG-101

Страница 1: ...Keep this INSTRUCTION MANUAL with care and refer to it when necessary In the event of any discrepancies the original INSTRUCTION MANUAL in Japanese is to be of final authority Office Jl Radin Inten II...

Страница 2: ...MC mode Accuracy 3 read out value Mode Broad leaf tree Hard Conifer Soft Moisture content comparison Average Value Display Max 20 points of average value data Switch off to delete Display LCD indicat...

Страница 3: ...o a normal measurement And POWER OFF also releases the mode Mode Change Key G It turns to H Broad leaf tree HARD S Conifer SOFT or MC 6 Moisture content mode for each moisture measurement Numerical va...

Страница 4: ...be connector receptacle This is a connector to be hooked up to a probe Hand strap To protect this instrument from dropping make sure that the hand strap be hung through over an operator s wrist Batter...

Страница 5: ...erval of 3 minutes without operation of measuring will automatically switch off Press Power SW to ON or OFF at an interval of 3 to 5 seconds to prevent operating errors 4 3 Changes of Measuring Mode W...

Страница 6: ...displayed Press and hold a key until it has reached to a desired upper limit value Keeping the key pressed changes to a fast winding of numerical values Release your finger of the key when the values...

Страница 7: ...ame procedures during measuring in process Hold mode or Non Hold mode When Upper Limit Value is unnecessary for an initial operation press again the H key after pressing first the H key In this case t...

Страница 8: ...not probe other object until the above sounds of 3 times has finished otherwise that may cause measurement errors An indicated value does not change when a measured value indicates not more than the...

Страница 9: ...d each measured value can also be confirmed respectively And then HOLD or AVE is not indicated During this mode Auto Power OFF can not be operated An Average Value Mode can not return to a measuring o...

Страница 10: ...easurement mode as well as when measuring Moisture can use all the functions although each of them does not display 7 About Temperature Compensating Automatic Temperature Compensating Function is set...

Страница 11: ...o to to to to to to above or above or below to to to to to to to Moisture Kind of wood Ash Elm Japanese oak Linden Beech Cherry tree Chestnut tree Katsura wood Birch Oak Zelkova Apitong Castor aralia...

Страница 12: ...battery case placed on the backside of a main body replace all the old batteries with new ones watch battery life Alkali dry battery LR03 4 In case batteries are kept used with a battery mark 1 the m...

Страница 13: ...hecked and a measuring mode without fail 11 2 Needle electrode cover Attaching and detaching of Needle electrode cover As illustrated below insert the needle electrode cover to the electrode by pinchi...

Страница 14: ...drop off the body Storage This moisture meter incorporates a Liquid Crystal Display LCD If the display is heated above 50 120 F it may be damaged This can happen if the moisture meter is left in a car...

Отзывы: