At a real time measuring, it sounds a buzzer “ Peep, Peep, Peep “ when a measuring value exceeds a setting 

value, and the upper limit value and the measuring value alternately blinks on the display while being probed to 

contact. Releasing the probe turns to

LLL

on display.

 

 

・ 

At a Hold Mode measuring, when it exceeds the setting value and even after releasing the probe off the object, 

the upper limit value and the measured value are alternately kept blinking. 

 

 

 

 

Press a

H

key 

  again and repeat the same procedures as before to change upper limit values. 

Possible to operate the same procedures during measuring in process (Hold mode or Non-Hold mode). 

When Upper Limit Value is unnecessary for an initial operation, press again the 

H

key after pressing first 

 the

H

key. In this case the Upper Limit Value is set at 50%, Maximum. 

To delete an Upper Limit Value, set the Upper Limit Value at 50 % or switch Power to OFF. 

    And the Upper Limit Value will also be deleted when Power switches OFF with Auto-Power-Off. 

 

4-6 Changes of Key -Lock Mode 

A press of a Lock Key 

  locks all the keys except Power SW 

 and  

prevents erroneous operations. Switch off Power to release. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Office: Jl. Radin Inten II No. 62 Duren Sawit, Jakarta 13440 - Indonesia
Workshop: Jl. Pahlawan Revolusi No. 22B, Jakarta 13430 - Indonesia
Phone: 021-8690 6777 (Hunting)

Fax: 021-8690 6777

Mobile: +62 816 1740 8925

Содержание TG-101

Страница 1: ...Keep this INSTRUCTION MANUAL with care and refer to it when necessary In the event of any discrepancies the original INSTRUCTION MANUAL in Japanese is to be of final authority Office Jl Radin Inten II...

Страница 2: ...MC mode Accuracy 3 read out value Mode Broad leaf tree Hard Conifer Soft Moisture content comparison Average Value Display Max 20 points of average value data Switch off to delete Display LCD indicat...

Страница 3: ...o a normal measurement And POWER OFF also releases the mode Mode Change Key G It turns to H Broad leaf tree HARD S Conifer SOFT or MC 6 Moisture content mode for each moisture measurement Numerical va...

Страница 4: ...be connector receptacle This is a connector to be hooked up to a probe Hand strap To protect this instrument from dropping make sure that the hand strap be hung through over an operator s wrist Batter...

Страница 5: ...erval of 3 minutes without operation of measuring will automatically switch off Press Power SW to ON or OFF at an interval of 3 to 5 seconds to prevent operating errors 4 3 Changes of Measuring Mode W...

Страница 6: ...displayed Press and hold a key until it has reached to a desired upper limit value Keeping the key pressed changes to a fast winding of numerical values Release your finger of the key when the values...

Страница 7: ...ame procedures during measuring in process Hold mode or Non Hold mode When Upper Limit Value is unnecessary for an initial operation press again the H key after pressing first the H key In this case t...

Страница 8: ...not probe other object until the above sounds of 3 times has finished otherwise that may cause measurement errors An indicated value does not change when a measured value indicates not more than the...

Страница 9: ...d each measured value can also be confirmed respectively And then HOLD or AVE is not indicated During this mode Auto Power OFF can not be operated An Average Value Mode can not return to a measuring o...

Страница 10: ...easurement mode as well as when measuring Moisture can use all the functions although each of them does not display 7 About Temperature Compensating Automatic Temperature Compensating Function is set...

Страница 11: ...o to to to to to to above or above or below to to to to to to to Moisture Kind of wood Ash Elm Japanese oak Linden Beech Cherry tree Chestnut tree Katsura wood Birch Oak Zelkova Apitong Castor aralia...

Страница 12: ...battery case placed on the backside of a main body replace all the old batteries with new ones watch battery life Alkali dry battery LR03 4 In case batteries are kept used with a battery mark 1 the m...

Страница 13: ...hecked and a measuring mode without fail 11 2 Needle electrode cover Attaching and detaching of Needle electrode cover As illustrated below insert the needle electrode cover to the electrode by pinchi...

Страница 14: ...drop off the body Storage This moisture meter incorporates a Liquid Crystal Display LCD If the display is heated above 50 120 F it may be damaged This can happen if the moisture meter is left in a car...

Отзывы: