Programming Functions (cont’d)
USERS (Continued)
User Enable/Disable (By User Number)
• User Number must be between 2 and 2000.
NOTE: Will Enable/Disable Users even if the User is associated with an enabled Group. Use Feature 3 to disable a specific User
Number and their associated User Code. If the disabled User Code is entered, the lock will flash 1 Green and 4 Red Flashes (with
1 long and 5 short beeps) indicating that the User Code exists in memory, but is disabled. Function 4 will "undo" Function 3.
3. Disable User
4. Enable User
;
3
;
[ ______ ] :
(User Number)
;
4
;
[ ______ ] :
(User Number)
5. User Enable with Timeout
(Enter Timeout, XXX Hours)
(This Function enabled through keypad only)
;
[ ______ ]
(User Number)
II^ P l [ ______ ] IICQl
(XXX Hours)
With Function 5, User Numbers must be between 2-2000, hours must be between 1-999.
Function 5 can
temporarily
override a disabled User (disabled using Function 3 above).
Since this is a temporary feature, Function 5 can only be enabled using the keypad.
Example: Brian, User Number 1157, rarely works at the office, but when he does, enable him for his
8
hour work day by entering
Program Mode and pressing: II^O l 11^3 II^O l I I C P l ll C P l ll ^ 3 ^ ^ 11^3 1 1 ^ 3 1 1 ^ 3 3 ^ 1 IICQl.
NOTE: Up to 4 Timeout Functions may be pending at any one time. An error beep will sound when attempting to program more
than 4 Timeout Functions.
User Lockout Mode
Prevents all User Codes (Except User 1 Code) from operating the lock. Note: No other programming
functions or schedules will re-enable Users. Users must be re-enabled with Function 7.
Note: Does not change the User enable/disable status. Note: If the lock is currently in Passage Mode
(door "unlocked") and Function
6
is programmed, the lock will remain in Passage Mode.
6. Enable Total User Lockout Mode
I^Q
1^3
(This Function enabled through keypad only)
Note: Do not use this function with Passage Mode.
7. Disable Total User Lockout Mode
(This Function enabled through keypad only)
M
8. Reserved
9. Enable User 300
(Service Code)
Service Code is a One-Time-Only Code. Once it is used, it is disabled until enabled again.
NOTE: User Number 297 is used to reset Service Code Use. See "Terminology Used in
this Manual" on page 7 for more information and examples regarding special Users 297-300.
10. Erase All Users Except the Master Code
(U ser
1
)
(This Function enabled through keypad only)
Erases all User Codes except the Master Code (User 1).
• Function 10 can only be performed using the keypad.
M
11. Reserved
2
2
16