Technical Specifications

  

 

SRD 20 

SRD 27 

SRD 36

CE Certificate 

No 0694BU3121 

0694BU3121 

0694BU3121

Types of Flue Application 

 

B23p-B33-C13-C33-C43-C53-C63-C83-C93 B23p-B33-C13-C33-C43-C53-C63-C83-C93 B23p-B33-C13-C33-C43-C53-C63-C83-C93

Gas Category 

 

II2H3B/P 

II2H3B/P 

II2H3B/P

Heating Inlet Max. 

kW 

18 

25 

34

Domestic Hot Water Inlet Max. 

kW 

23.5 

25 

34

Heating Inlet Min. 

kW 

4 (G20/G25) - 5.5 (G30/G31) 

10

Heating Outlet Max. (50/30°C) 

kW 

19.26 

26.68 

36.24

Efficiency at 100% load (50/30°C) 

107 

106.7 

106.60

Efficiency at 30% load (50/30°C) 

108.1 

106.3 

107.90

Heating Outlet Max. (80/60°C) 

kW 

17.69 

24.6 

33.42

Heating Outlet Min. (80/60°C) 

kW 

3.9 (G20/G25) - 5.4 (G30/G31) 

8.73 

9.73

Efficiency at 100% load (80/60°C) 

98.3 

98.4 

98.3

Efficiency at 30% load (80/60°C) 

101.1 

100.1 

100.7

According to the Gas Directive 92/42/EEC Efficiency marking

  

HHHH

 

HHHH

 

HHHH

Heating Circuit

Heating Temperature Setting Range (min.-max.) 

°C 

30-80 / 25-40 

30-80 / 25-40 

30-80 / 25-40

Max. Heating Operation Temperature 

°C 

95 

95 

95

Expansion Tank Capacity 

liter 

7

Max. Operating Pressure (Heating) 

bar 

3

Min. Operating Pressure (Heating) 

bar 

0.3 

0.3 

0.3

Domestic Hot Water Circuit

Domestic Hot Water Temperature Setting Range (min.-max.)

 °C 

35-60 

35-60 

35-60

Max. Hot water Operating Pressure 

bar 

6

Min. Hot water Operating Pressure 

bar 

0.5 

0.5 

0.5

Hot Water Flow Rate (

t:

 

30°C) 

liter/min. 

11.53 

12.25 

16.63

Dimensions

Width 

mm 410 

410 

410

Height 

mm 

730 

730 

730

Depth 

mm 292,5 

292,5 

324,5

Weight (net) 

kg 

38 

40 

44

Flue Systems

Horizontal Concentric Flue System 

Ø mm 

60/100 

60/100 

80/125

Max. Flue Length 

8

Twin Flue System 

Ø mm 

80/80 

80/80 

80/80

Max. Flue Length (from terminal to terminal) 

50 

50 

50

Twin Flue System 

Ø mm 

60/60 

60/60 

60/60

Max. Flue Length (from terminal to terminal) 

m  

30 

30 

30

Vertical Concentric Flue System 

Ø mm 

60/100 

60/100 

80/125

Max. Flue Length 

8

Gas Consumption

Natural Gas G20 Gas Consumption 

m

3

/h 

1.9 

2.65 

3.60

Butane Gas G30 Gas Consumption 

kg/h 

1.42 

1.97 

2.68

Propane Gas G31 Gas Consumption 

kg/h 

1.4 

1.94 

2.64

Electrical Supply

Power Supply 

V/Hz 

230/50 

230/50 

230/50

Electricity Consumption 

133 

138 

138

Protection Class 

IP 

X4D 

X4D 

X4D

Содержание SUPER FIT 24

Страница 1: ...90540023 S L KON 27 1 Yayl Hortum Kelep esi 20 5 1103730 58990440126 TS 2500 1 SM 1 DIN 17223 B B Kalite yay eli i 26 1 Yayl Hortum Kelep esi 23 1103729 58990440127 TS 2500 1 SM 1 DIN 17223 B B Kalite...

Страница 2: ...Code No A 1 5 1i Publishing Date 020321 Revision Date 020321...

Страница 3: ...tart Up 14 2 7 Diagnostics Error Codes 16 2 8 Automatic Control Devices Optional 18 2 9 Automatic Operation of the Boiler In Accordance With Weather Temperature Optional 19 2 11 Solar Connection Set O...

Страница 4: ...ections 37 4 6 Appropriate Central Heating Pipes 39 4 7 Gas Connection 40 4 8 Electrical Connections 40 4 9 Flue Connection 43 5 COMMISSIONING THE APPLIANCE 50 6 PERIODIC MAINTENANCE AND CLEANING 50 6...

Страница 5: ...f the cable is damaged in any way sw appliance and have the cable replaced by a suitably qualified electrician When replacing the power supply cable only use cables of the same characteristics HO5 VV...

Страница 6: ...cs HO5 VV maximum external 8 mm When using an electrical appliance a few fundamental rules must be observed Do not touch the appliance with damp or wet parts of the body or when barefoot Do not pull o...

Страница 7: ...The manufacturer will not be held liable for any damage or injury caused as a result of an ineffective or non existent earth system The domestic power supply must be checked by a qualified electricia...

Страница 8: ...8 1 2 Declaration of Conformity...

Страница 9: ...th much wider heat transfer surface For flue gas temperatures under 55 C the water vapor inside the flue gas condenses i e transforms to liquid from gas form Thus energy is captured before going out t...

Страница 10: ...and windows to vent the room CLOSE gas valves of any appliance CLOSE gas valves at the building and apartment inlet DO NOT LIGHT anything and DO NOT SMOKE DO NOT TOUCH electric buttons DO NOT SWITCH f...

Страница 11: ...near the boiler Do not place cooker near the appliance and protect the boiler from direct vapor The boiler is to be connected to an earthed 230 V 50 Hz electric supply Toenablethefrostprotectionfuncti...

Страница 12: ...Heating Only Off 2 Reset button 3 Heating water temperature decrease button 4 Heating water temperature increase button 5 Domestic hot water DHW temperature increase button 6 Domestic hot water DHW t...

Страница 13: ...re 3 Filling operation must last until 1 2 bar value is seen on the manometer Figure 2 If the water pressure falls down under a certain value E04 error is seen on the screen In order to increase the p...

Страница 14: ...of the flame is shown with a flame symbol on the display During DHW usage the tap symbol on the display blinks WINTER Mode In order to operate the combi boiler in WINTER mode press key 1 Figure 1 and...

Страница 15: ...Section 2 8 If code E04 appears on the display 7 this denotes that there is no water in the boiler Consequently fill the system as described in Section 2 6 Setting Heating CH Temperature The heating...

Страница 16: ...error code that is not listed below please call an authorized Service Centre No Flame or Spurious Flame This error code appears if there is no flame ionization current sensed on the burner In this cas...

Страница 17: ...t tap to the appliance 3 Open filling tap located under the appliance If filling tap opens in these conditions water in the CH system evacuates from HOT water tap Check pressure value from the manomet...

Страница 18: ...ose of comfort and fuel economy 1 On off control devices a Room Thermostat You can use room thermostat with your boiler to maintain desired room temperature Analog and digital wired and wireless model...

Страница 19: ...thorized installers or services to buy any of these options Do not forget to ask for user manual of the device You can get more detailed information from our web site www alarko carrier com tr 2 9 Aut...

Страница 20: ...ank to the solar connection set which can be supplied as accessory with Super Fit There is no need for any electronic control system Schematics of a working system is shown in Figure 4 solar connectio...

Страница 21: ...sends domestic hot water to the combi boiler to be heated to demanded temperature Temperature of domestic hot water coming from combi boiler is also set before being sent to the taps Setting temperat...

Страница 22: ...suitable for the LPG consumption of the combi model you will use These consumption values are 1 7 2 0 and 2 3 kg h for SUF 24 28 35 models respectively If you smell gas turn the tubes off and follow t...

Страница 23: ...23 3 TECHNICAL CHARACTERISTICS 3 1 Technical Data...

Страница 24: ...ation Low temperature regime means 30 C for condensing boilers 37 C for low temperature boilers and 50 C for for other appliances on return temperature Auxiliary electricity consumption Other items Fo...

Страница 25: ...ntary heating system Combination Heater Model s SUF 35 Condensing Boiler s Low Temperature Boiler s Yes No No No No Yes Item Symbol Value Unit Item Symbol Value Unit Seasonal space heating energy effi...

Страница 26: ...26 3 4 Dimensions 3 4 Dimensions Figure 7 Dimensions Figure 7 Dimensions Gas Inlet...

Страница 27: ...OMETER 28 PLASTIC DRAINAGE FITTING S B A 1 3 2 4 3 4 C R 1 2 5 6 7 8 5 6 7 8 9 9 10 10 11 11 12 12 E D F G H I 13 13 14 14 15 15 J K L M N O P 60 1 Gaz Vanas S zd rm 59 1 R Toz K r Tapa M12 58 10 Sac...

Страница 28: ...AFETY VALVE 9 AUTOMATIC AIR VENT 10 LIMIT THERMOSTAT 11 HEATING WATER FLOW TEMPERATURE SENSOR 12 PUMP 13 PRESSURE SWITCH 14 FLUE FUSE 15 EXPANSION TANK 16 DOMESTIC HOT WATER DHW TEMPERATURE SENSOR 17...

Страница 29: ...ng circulation pump is 0 20 3 7 Circulation Pump Circulation Pump Performance Chart SUF 24 28 Circulation Pump Performance Chart SUF 24 28 Variable Differential Pressure Curve Curve 1 Constant Differe...

Страница 30: ...al Pressure Curve Curve 1 Constant Differential Pressure Curve Curve 2 Constant Speed 3 Stages Curve Curve 3 Curve 1 setting Curve 2 setting Curve 3 setting Figure 11 SUF 35 pump performance chart Fig...

Страница 31: ...ycle Timed pump overrun function on CH and DHW cycles CH CH antifreeze DHW DHW antifreeze chimney sweeper cycles Anti freeze function on CH and DHW cycles Chimney sweeper function Alternative pump con...

Страница 32: ...Icon 3 lights while parameter and service info menu is used Icon 4 Icon 4 lights when flame exists in system Icon 5 Reset When the boiler is switched off at the switch on the control panel the word O...

Страница 33: ...6 EU Regulation on appliances burning gaseous fuels 811 2013 Energy labelling of space heaters and combination heaters 813 2013 Ecodesign requirements for space heaters and combination heaters 2014 35...

Страница 34: ...4 3 Packaging and Transportation The boiler is packaged in a cardboard box Warning signs are to be observed during transport and storing 4 3 Packaging and Transportation The boiler is packaged in a c...

Страница 35: ...35 Opening the Package Opening the Package Figure 13 Opening the package...

Страница 36: ...2 Opening the Package 4 4 Installation of the Boiler Figure 23 Opening the package Figure 25 Mounting Instructions 4 4 Installation of the Boiler The appliance must be installed exclusively on a flat...

Страница 37: ...der pump Figure 16 see Detail A must be tightened with torque of maximum 18 Nm in case of rubber gasket use This value is 30 Nm in case of cylinder head gasket use To prevent vibration and noise comin...

Страница 38: ...here the circuit is frequently topped up or when the system is often either partially or fully drained The outlet connection of the boiler safety valve must be connected to a discharge trap The manufa...

Страница 39: ...gen Barrier These systems are not recommended to use In case of use oxygen absorption to underfloor heating system may happen and green colored biocide bacterium may propagate and accumulate as colony...

Страница 40: ...for which the appliance has been set up see gas type label inside the boiler The gas supply pressure must be between the values reported on the rating plate see gas type label inside the boiler Prior...

Страница 41: ...d by the user if the cable is damaged in any way switch off the appliance and have the cable replaced by a suitably qualified electrician When replacing the power supply cable only use cables of the s...

Страница 42: ...oom thermostat connections to terminal board as follows a Switch off the power supply at the main switch b Remove the front case panel of the boiler c Bend the plastic panel holding sheets to the side...

Страница 43: ...stions must be taken into consideration for flue installation Horizontal air intake pipes must slope downwards by 3 at the wall towards atmosphere to prevent the entry of rain water dust or impurities...

Страница 44: ...cifically designed for condensing boilers Traditional flue components cannot be used for conveying exhaust fumes from condensing boilers nor vice versa Below suggestions must be taken into considerati...

Страница 45: ...roof Outlets are close to each other at the same pressure area C33 x Combustion air intake and flue gas discharge with vertical outlet Outlets are close to each other at the same pressure area C43 x C...

Страница 46: ...46 Figure 24 Flue applications...

Страница 47: ...can be connected directly to the outside or can be connected to a suitable combined flue system MAXIMUM FLUE LENGTH 8 m The maximum flue length linear equivalent is obtained by summing the length of l...

Страница 48: ...exhaust gases and draws combustion air through two separate pipes MAXIMUM FLUE LENGTH 80 80 50 m The maximum flue length linear equivalent is obtained by summing the length of linear pipe and the equ...

Страница 49: ...ir while the 60 mm plastic inner pipe discharges the exhaust fumes MAXIMUM FLUE LENGTH 8 m The maximum flue length linear equivalent is obtained by summing the length of linear pipe and the equivalent...

Страница 50: ...E AND CLEANING 6 1 Periodic Maintenance of the Combi Boiler Authorized Service During and also after guarantee period you must keep taking maintenance once a year before winter to provide safe use fue...

Страница 51: ...nsion tank pressure filling if low Control of flue leak proofing Flue gas analysis and combustion control Leakage control of pipe and venturi lines after gas valve with detector or detergent foam Clea...

Страница 52: ...52...

Страница 53: ...53...

Страница 54: ...54...

Страница 55: ...55...

Страница 56: ...water Operating Pressure bar 6 6 Min Hot water Operating Pressure bar 0 5 0 5 Hot Water Flow Rate t 30 C liter min 11 53 12 25 Dimensions Width mm 410 410 Height mm 730 730 Depth mm 292 5 292 5 Weigh...

Отзывы: