51
6.2 Maintenance Content
Maintenance includes below points:
• Main heat exchanger cleaning
• Control of burner and electrode
• Fan motor balance control and fin cleaning
• Control of thermostat and sensors
• Cleaning of siphon
• Control of condensate water drain
• Control of expansion tank pressure, filling if low
• Control of flue leak proofing
• Flue gas analysis and combustion control
• Leakage control of pipe and venturi lines after gas valve with detector or
detergent foam
• Cleaning of filters
• Cleaning of dirt separators
• Control of accurate operating of the appliance
• Filling the authorized service form
6.3 Cleaning of the Combi Boiler (User)
Wipe the outer case of the appliance with soft, humid fabric. Don’t use hard,
abrasive cleaning materials.