4.4 Installation of the Boiler
■
The appliance must be installed
exclusively on a flat vertical solid
wall capable of supporting its
weight.
■
The boiler should be fitted within
the building unless protected by
a suitable enclosure in an open
area such as garage, balcony.
In this manner, the boiler can be
fitted inside a cupboard. Contact
Alarko Carrier for proper cup-
board dimensions.
■
If the boiler is sited in an unheat-
ed enclosure then it is recom-
mended to leave the power on to
give frost protection. Frost pro-
tection is active even if the appli-
ance is in OFF position.
Figure 14.
Minimum installation clea-
rances.
■ If the boiler is installed in a room containing a bath or shower, reference
must be made to the national standards and local requirements.
In order to allow access to the interior of the boiler for maintenance pur-
poses, it is important that the necessary clearances indicated in Figure 14
are respected.
For mounting the appliance, it is required to follow the below instructions
(Figure 16). Determine the right position for the boiler with respect to the
required clearances for servicing and the position of the flue.
Firstly, mark the fitting points on the wall by means of mounting template
located in packaging box and a spirit level (Figure 14 – Step 1). Mount the
L screws together with wall plugs from the marked points. Finally, hang the
boiler from L screws (Figure 15 – Step 2).
Содержание SRS 20
Страница 1: ...SERADENS SUPER SRS 20 28 36 PREMIX CONDENSING BOILER INSTALLATION AND OPERATING INSTRUCTIONS ...
Страница 2: ...Code No A 1 4 8i Publishing Date 100616 Revision Date 100616 ...
Страница 27: ...27 3 2 Dimensions SRS 20 28 36 Figure 5 Dimensions ...
Страница 37: ...37 Figure 13 Opening the Package Opening the Package ...
Страница 56: ...56 ...
Страница 57: ...57 ...
Страница 58: ...58 ...
Страница 59: ...59 ...