Operation and Maintenance Manual
2020
Version 1.5
20
Figure 3.3.2-1
3.3.2. Hydraulic Reversing Deflector Control System
The system is available for AJ 230. It includes a rotary valve which simplifies the
system considerably.
The reversing deflector is controlled (cf. figure 3.3.2-1) mechanically with a cable (A)
which operates the valve regulator (B).
The cylinder gets its power from the oil pump which has been integrated in the
propulsion unit.
In a stock delivery, the system does not include a control lever or a cable, so their type
varies depending on the boat manufacturer. However, the different types of systems
have the following things in common:
- The operation of the deflector must be separate from the throttle and the gear.
- The stroke length of the cylinder is always the same.
- The incoming direction of the cable can be chosen freely.
The
oil circulating in the system must be cooled
in order to prevent excessive heating.
This is done with a separate heat exchanger or a possible cooler in the engine.
B
A
Содержание AJ 160
Страница 1: ......
Страница 36: ...APPENDIXES Operation and 36 Maintenance Manual Version 1 5 Appendix 2 SE 01...
Страница 37: ...Version 1 5 37 APPENDIXES Operation and Maintenance Manual Appendix 3 SE 02...
Страница 40: ...APPENDIXES Operation and 40 Maintenance Manual Version 1 5 Appendix 6 WARRANTY OWNERSHIP...