![AL-KO Solo Robolinho 110 Скачать руководство пользователя страница 66](http://html1.mh-extra.com/html/al-ko/solo-robolinho-110/solo-robolinho-110_instructions-for-use-manual_2888002066.webp)
GB
66
Robolinho 1100/110
Help in case of malfunction
Fault code
Cause
Remedy
CN012: Cal: no loop
CN015: Cal: outside
Fault during the calibration:
■
The appliance cannot
find the boundary cable.
■
Check the LEDs on the base sta-
tion.
■
Check the power source of the base
station. Disconnect and reconnect
the transformer.
■
Place the appliance at the pre-
scribed calibrating position; align
precisely at right angles. Appliance
must be able to drive over the
boundary cable.
CN017: Cal: signal
weak
Fault during the calibration:
■
Loop signal too weak
■
No loop signal
■
The boundary cable is
faulty.
■
Place the appliance at the pre-
scribed calibrating position; align
precisely at right angles.
■
Check the power source of the base
station. Disconnect and reconnect
the transformer.
■
Check the boundary cable for dam-
age.
CN018: Cal: Colli-
sion
Fault during the calibration:
■
The appliance has
bumped into an obstacle.
Remove the obstacle.