Box Contents & Specifications

1x 

3x 

Stock Code: 25470

AKW M11 DigiPump

 

Supply: 230V aC 50Hz 100W
Ingress Protection: IP45
Duty Cycle: 50% Max 30 Mins. on
for use with electric & mixer showers.
Pump and controller enclosed in one unit.
Max flow rate: 11 litres Per Minute (lPM).
non-handed, selectable inlet/outlet direction.
Max Head: 1.0m (39in)
Max lift: 0.5m (20in)

1x 

3x 

2x 

22mm

2x 

22mm

Supply: 230V aC 50Hz 100W   

   

Ingress Protection: IP45
Duty Cycle: 50% Max 30 Mins. on 

 

for use with electric & mixer showers.
Pump and controller enclosed in one unit.
Max flow rate: 17 litres Per Minute (lPM)
non-handed, selectable inlet/outlet direction.
Max Head: 1.0m (39in)
Max lift: 0.5m (20in)

Supply: 230V aC 50Hz 100W   

   

Ingress Protection: IP45
Duty Cycle: 50% Max 30 Mins. on 

 

for use with electric & mixer showers.
Pump and controller enclosed in one unit.
Max flow rate: 20 litres Per Minute (lPM)
non-handed, selectable inlet/outlet direction.
Max Head: 1.0m (39in)
Max lift: 0.5m (20in)

Confirm you have all the correct parts required. Ensure the volume of water from the shower does not exceed the 

pumps drainage capacity. note: Increased Head/lift conditions will affect the pump’s performance.

AKW M20 DigiPump

1x 

3x 

2x 

22mm

3x 

1x  15mm               

1x  15mm               

1x            

1x 22mm

1x 22mm

1x

2x 

MI

N

100mm MIN

*

HEAD

LIFT

*

*

*

MI

N

100mm MIN

*

HEAD

LIFT

*

*

*

3x 

1x

1x

2x 

MI

N

100mm MIN

*

HEAD

LIFT

*

*

*

MI

N

100mm MIN

*

HEAD

LIFT

*

*

*

3x 

1x

1x

2x 

MI

N

100mm MIN

*

HEAD

LIFT

*

*

*

MI

N

100mm MIN

*

HEAD

LIFT

*

*

*

2x 

22mm

Contents

Stock Code: 25450

AKW M17 DigiPump

Stock Code: 25460

Содержание 25450

Страница 1: ...ease read all instructions before installation and leave this document with the end user for future reference as it contains important warranty information M Series DigiPumps INSTALLATION AND USER MANUAL ...

Страница 2: ...ortant Safety and Electrical Information 6 Preparing the Pump 7 Fixing Pump to Surface 8 Setting Flow Direction 9 Plumbing Connections 10 Fitting Flow Sensor s 11 Connecting the Flow Sensor s 12 Pump Set Up 13 Pump Settings 14 Commissioning Checks 15 Care and Maintenance 16 Trouble Shooting 17 19 Notes 20 21 Warranty 22 Activate Warranty 23 Contact Us 24 ...

Страница 3: ...Litres Per Minute LPM Non handed selectable inlet outlet direction Max Head 1 0m 39in Max Lift 0 5m 20in Supply 230V AC 50Hz 100W Ingress Protection IP45 Duty Cycle 50 Max 30 Mins on For use with electric mixer showers Pump and controller enclosed in one unit Max flow rate 20 Litres Per Minute LPM Non handed selectable inlet outlet direction Max Head 1 0m 39in Max Lift 0 5m 20in Confirm you have a...

Страница 4: ... must be located away from the direct line of water jets Zone 1 lies above Zone 0 up to a minimum of 2 25m or to the height of the fixed shower head from the finished floor level which ever is greater If the shower has no tray then zone 1 extends to 1 2m around the fixed shower head Zone 2 is the area extending 0 6m beyond Zone 1 and up to the same height as Zone 1 FOR GUIDANCE ONLY PLEASE REFER T...

Страница 5: ...sealed against water ingress The case must not be cut except for the thin rear shroud Do not pierce casing Use the supplied Pump Spacers kit to route the cables behind the unit The clearance behind the unit and separation from the wall must be minimal and the gap must not be sealed All casing cable glands must be visually checked for presence of the elastomeric centre sealing grommet and tightness...

Страница 6: ...es at SELV is located within the outer cover CAUTION CAUTION READ INSTRUCTIONS BEFORE INSTALLING THIS PRODUCT CAUTION CAUTION READ INSTRUCTIONS BEFORE INSTALLING THIS PRODUCT CAUTION CAUTION READ INSTRUCTIONS BEFORE INSTALLING THIS PRODUCT CAUTION 230V AC Lethal Voltage present on the AC supply Ensure mains power supply is switched OFF before starting wiring DO NOT take risks with plumbing or elec...

Страница 7: ...e cables being trapped Separate the spacers remove the adhesive backing and snap lock into position Connecting Auxiliary On Off Switch to Pump optional Flow Sensor Cables Power Cable Auxillary On Off Switch Cable Stock Code 25488 Connection for Auxillary Switch Flow Sensor Cables Power Cable Auxillary On Off Switch Cable Stock Code 25488 Connection for Auxillary Switch ...

Страница 8: ...a finished surface Pipe connections must be easily accessible and a clearance of 100mm around the base and sides is recommended Using the back plate as a template mark the fixing holes Drill and plug the wall taking care there are no hidden cables or pipes Use all the screw fixing positions Mount the pump to the finished surface using all the wall fixings Use the Pump Spacers to prevent the cables...

Страница 9: ... Check that the flow is in the required direction reverse as required Loosen the pump head housing rotate and fully tighten home The pipework to this high performance pump must be clamped down effectively AKW advise and recommend you clamp pipework either side of joints junctions or connections and at a maximum of 500mm between other supports Remove shipping tapes from pump inlet and outlet Refit ...

Страница 10: ... Max 0 5m Max LIFT Shower Head Waste outlet pipe NOT PREFERRED PREFERRED NO ELBOWS Shower Tray Waste MINIMISE PIPEWORK LENGTH WHEREVER POSSIBLE OR 100mm 4in MIN GAPS Use the supplied Pipe Adaptors to connect to waste outlet pipe For best performance locate within 1m 39in of shower and minimise the number of lifts bends and the length of all pipes connecting the pump to the waste outlet pipe Note I...

Страница 11: ... on the sensor casing is in the correct orientation with the flow of water Allow enough distance so that the sensors are easily accessible Ensure all cable connections are accessible and in a dry location Fit sensor using an approved liquid based thread sealant suitable for nylon threads Connect the sensor tail cable from the flow sensor to the pump sensor cable see page 12 Do not tile over the fl...

Страница 12: ... two water feeds connect both flow sensors Fit one flow sensor to cold water feed pipe and one to the hot water feed pipe For electric showers only connect one sensor the other sensor wire must be terminated in a connector block and insulated using electrical insulation tape at a dry location Failure to do this may damage the pump Note To connect the pump directly to a compatible electric shower p...

Страница 13: ...pump runs slower If the water level rises increase the value on the display so the pump runs faster Auxiliary Switch Type The DigiPump accepts two switch types latching or momentary This function manually starts stops the pump The pump will stop automatically after 30 minutes if not stopped manually This is an optional extra AKW Stock Code 25488 Start Delay The time before the pump starts after th...

Страница 14: ...ge adjustment 00 99 To change the value Up Press and release RUN button Down Press and release DELAY button Exit to Auxiliary switch type press and release TEST button AUXILIARY SWITCH TYPE TYPE 00 Latching 01 Momentary Up Press and release RUN button Down Press and release DELAY button Exit to standby Press and release TEST button START DELAY From Standby press and release DELAY button to increme...

Страница 15: ...ctions Failure to do so may void warranty Confirm all push fit pipes are fully inserted 20mm into fittings Brush out all dust grit and debris from shower tray Thoroughly clean out waste Confirm shower water supply pipework is flushed before connecting to the shower sensor via the filter Turn on power to Pump Turn shower on Low Flow and confirm pump operates after Start Delay default 5 secs Run for...

Страница 16: ...k connections must be made to the unit with sufficient clearance 100mm minimum separation to any pipe bend or fitting adjacent to the inlet outlet connections to permit removal of the pump head for routine maintenance and replacement The unit must be regularly cleaned using normal bathroom cleaning materials and rinsed down with clean water and wiped dry with a soft cloth to remove any cleaning re...

Страница 17: ... work to be undertaken Check power supply to the unit Check the wiring to the pump Check the cable to the pump Check water pressure to the shower is sufficient to activate the flow sensor check the flow sensor is fitted in the correct orientation Check flow sensors wired correctly Re pair the pump and the shower if a wireless connection Check calibration settings should be over 50 Test flow sensor...

Страница 18: ...ecks and work to be undertaken Check for damage to the non return valves Check diaphragm for damage Check C clips are installed to the inlet and outlet pipework Check the direction of flow of the pump head Check the non return valves are correctly fitted Adjust the calibration and settings Attach temporary pipework to the inlet side of the pump and get it to discharge water from a bucket when show...

Страница 19: ... lowest level via gravity Checks and work to be undertaken Adjust the settings and calibration on the pump Check C clips are installed to the inlet and outlet pipework Make sure is firmly fixed to a wall and ideally a solid wall Make sure is firmly fixed to a wall and ideally a solid wall Settings should be changed from factory setting which are Delay 5 seconds Run on 20 seconds Calibration 50 sec...

Страница 20: ...General 01905 823 298 www akw ltd co uk 20 20 Notes Notes ...

Страница 21: ...Technical Support 01905 560 219 21 Order 01905 823 299 orders akw ltd co uk 21 Notes Notes ...

Страница 22: ...he UK or the Republic of Ireland and with prior agreement Any action taken under this warranty does not extend the stated 5 year expiry date NOT COVERED BY THIS WARRANTY Warranty excludes general wear and tear through usage and this does not apply to inappropriate use inappropriate cleaning damage or defects that result from unauthorised modifications or repairs accidental damage lack of maintenan...

Страница 23: ... what the best practice for the installation is Due to the very wide variability of possible installation conditions AKW cannot provide all circumstances for the installation AKW cannot accept any liability in connection with this information or its use This information is provided on the condition that the person receiving it shall make his her own tests to determine the suitability for the parti...

Страница 24: ...td co uk General Enquiries 01905 823 298 sales akw ltd co uk Technical Enquiries 01905 560 219 technicalenquiries akw ltd co uk Kitchen Enquiries 01905 823 262 kitchens akw ltd co uk Fax 01905 823 297 AKW Pointon Way Hampton Lovett Droitwich Spa WR9 0LR www akw ltd co uk orders akw ltd co uk Contact Us ...

Отзывы: