background image

 

Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany 

www.AKTOBIS.de

 

Email: [email protected] 

 
 

Important safety instructions: 
 

 

Operate the unit only in a straight position and with a straight/level stance (Fig. 1) ! 

 

Make sure that no moisture gets into or onto the unit (Fig. 2) ! 

 

Make sure there is a minimum distance of approx. 40 cm to fixtures and walls (Fig. 3) ! 

 

Watch out for electricity, never walk into or insert objects into the appliance (Fig. 4) ! 

 

The unit is filled with the flammable refrigerant R290, therefore strictly follow the instructions of this manual and 
read it completely. (Fig. 5) 

 

Do not carry out any repairs on the unit yourself ! (Fig. 5) 

 

Do not place any objects on the appliance and make sure that the air intake and the exhaust air are always 
free! 

 

Supervise the air conditioner when children or animals are near the unit ! 

 

This air conditioner should only be operated by persons who have the necessary physical and mental 
capabilities to operate this unit without problems ! 

 

This air conditioner is only approved for indoor use ! 

 

Only qualified personnel or electricians are allowed to open the unit ! 

 

Only use the recommended voltage for operating the unit ! 

 

Make sure that the power cable is unfolded (untied) before connecting it to the socket ! 

 

Please do not use the power cable as a pull cable for the air conditioner !  

 

Make sure that the plug is cleanly and properly connected to the socket before using the appliance ! 

 

Never reach near the plug or socket with wet hands ! 

 

Make sure that flammable or explosive substances (e.g. gases/oils etc.) are never in the vicinity of the unit ! 

 

If you are not going to use the unit for a long time, switch it off and disconnect the mains plug ! 

 
Please switch off the unit immediately and disconnect it from the mains/power supply if anything 
seems to be wrong ! In this case, please contact a specialist and do not try to repair the unit 
yourself !!! 

 

Examples:

 Fan does not run during operation, fuse has blown or compressor rattles loudly. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

    Fig. 1 

 

 

  Fig. 2   

 

 

   Fig. 3  

 

Fig. 4 

  

 

 
 
 
 

Fig. 5 

Содержание WDH-FGA1075

Страница 1: ...per transport can sometimes occur despite careful instructions on the carton Therefore we ask you to let it stand upright for at least 4 hours before using it for the first time so that the refrigeran...

Страница 2: ...sary physical and mental capabilities to operate this unit without problems This air conditioner is only approved for indoor use Only qualified personnel or electricians are allowed to open the unit O...

Страница 3: ...ust air cold 6 air filter 7 condensation drain 8 mains plug compartment 9 air intake 10 air intake Accessories 11 adapter for connecting the warm air hose with the window slit shutter bar 12 exhaust a...

Страница 4: ...ng This warm exhaust air must be discharged to the outside You can either direct the warm exhaust air outside through a suitable hole 160 mm diameter in the wall similar to a kitchen extractor bonnet...

Страница 5: ...e extended from 30 cm to a maximum of 150 cm But for maximum effectiveness and economy we recommend the shortest possible length Warning The length of the exhaust air hose is specially adapted to the...

Страница 6: ...gnal light when fan operation is activated h Signal light during dehumidification operation i Signal light when heating mode is activated inactive on this unit type j Signal light when the water tank...

Страница 7: ...M Average operating strength C L Weak operating strength Note In automatic mode the operating strength is set automatically by the unit The operating level you have just selected is indicated by a sma...

Страница 8: ...es not included 9 Error display The air conditioner detects malfunctions and displays them in the unit s display panel If the display field shows E1 or E2 please contact your dealer 10 Other operating...

Страница 9: ...zontally Now the condensation water can drain out of the tank 4 If your drip tray is full but there is still water in the condensation tank simply put the rubber plug back on the drain hole and then e...

Страница 10: ...acent illustration Use the original carton to store the air conditioner Troubleshooting The unit does not switch on Check the mains plug and try a different socket Check if the house fuse has popped o...

Страница 11: ...930 watts Energy efficiency ratio EER 2 6 Unit type Cooling only Cooling type Air cooling Noise emission 65 dB A Voltage 220 240V 50Hz Max Power consumption 1 130 W 5 0 A Power consumption in operatin...

Страница 12: ...tage or non observance of the assembly instructions Completely or partially dismantled units Conformity The air conditioner has been tested and itself and or parts thereof have been manufactured under...

Отзывы: