2.  Selection of the operating mode 

 

Press the 

MODE

 button 

to select the desired operating mode:

 

A)   

= Automatic mode / Auto mode (

see point 5.

)  

B)   

= Cooling mode 

C)   

= Fan operation 

D)               = Dehumidification mode 

 
The operating mode you have just selected is indicated by a small signal light ! (See also the functional description 
of the control panel) 

 

3.  Setting the temperature target 

 

Press the "UP button" (to increase the room temperature) or the "DOWN button" (to decrease the room 
temperature) until you have selected your desired temperature target in the display field. 
 
Note: The temperature target is only displayed while the UP/DOWN key is pressed. After a short wait, the display 
field shows the current room temperature again. You can set your target temperature between 18°C - 32°C ! 

 

4.  Setting the operating strength 

 

Press the SPEED button (SPEED = air circulation speed setting) to select your desired operating speed:

 

 

A)  H = High operating strength 
 
B)  M = Average operating strength 

 

C)   L = Weak operating strength 

 

Note: In automatic mode, the operating strength is set automatically by the unit ! The 

operating level you have just 

selected is indicated by a small signal light next to the key ! (See also the functional description of the control 
panel). 

 

5.  Using the automatic mode / Auto mode 

 

By selecting automatic mode, the air conditioner attempts to reach or permanently maintain the factory-set 
temperature target of 24°C and then automatically switches off the compressor after this value is reached.

 

 
Note: Using the Auto mode on units without a heating function makes only limited sense, as the Auto mode was 
originally designed to maintain a constant temperature (automatic heating or cooling as needed). 

 

6.  Using the timer function 

 

If you want to activate/use the timer function (function for determining the remaining time or function for specifying a 
start time), press the TIMER key.

 

 
6.1. 

Determination of the remaining term: 

 

During operation, press the TIMER button to select the desired remaining time of the air conditioner. (A 
value between 1 - 24 hours can be selected). After this selected operating time has elapsed, the unit 
automatically switches off completely. 

 
 
 
 
 
 

Содержание WDH-FGA1075

Страница 1: ...per transport can sometimes occur despite careful instructions on the carton Therefore we ask you to let it stand upright for at least 4 hours before using it for the first time so that the refrigeran...

Страница 2: ...sary physical and mental capabilities to operate this unit without problems This air conditioner is only approved for indoor use Only qualified personnel or electricians are allowed to open the unit O...

Страница 3: ...ust air cold 6 air filter 7 condensation drain 8 mains plug compartment 9 air intake 10 air intake Accessories 11 adapter for connecting the warm air hose with the window slit shutter bar 12 exhaust a...

Страница 4: ...ng This warm exhaust air must be discharged to the outside You can either direct the warm exhaust air outside through a suitable hole 160 mm diameter in the wall similar to a kitchen extractor bonnet...

Страница 5: ...e extended from 30 cm to a maximum of 150 cm But for maximum effectiveness and economy we recommend the shortest possible length Warning The length of the exhaust air hose is specially adapted to the...

Страница 6: ...gnal light when fan operation is activated h Signal light during dehumidification operation i Signal light when heating mode is activated inactive on this unit type j Signal light when the water tank...

Страница 7: ...M Average operating strength C L Weak operating strength Note In automatic mode the operating strength is set automatically by the unit The operating level you have just selected is indicated by a sma...

Страница 8: ...es not included 9 Error display The air conditioner detects malfunctions and displays them in the unit s display panel If the display field shows E1 or E2 please contact your dealer 10 Other operating...

Страница 9: ...zontally Now the condensation water can drain out of the tank 4 If your drip tray is full but there is still water in the condensation tank simply put the rubber plug back on the drain hole and then e...

Страница 10: ...acent illustration Use the original carton to store the air conditioner Troubleshooting The unit does not switch on Check the mains plug and try a different socket Check if the house fuse has popped o...

Страница 11: ...930 watts Energy efficiency ratio EER 2 6 Unit type Cooling only Cooling type Air cooling Noise emission 65 dB A Voltage 220 240V 50Hz Max Power consumption 1 130 W 5 0 A Power consumption in operatin...

Страница 12: ...tage or non observance of the assembly instructions Completely or partially dismantled units Conformity The air conditioner has been tested and itself and or parts thereof have been manufactured under...

Отзывы: