background image

 

Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany 

www.AKTOBIS.de

 

Email: [email protected] 

 
 

Operating recommendations: 
 

For good cooling results and for the most effective and economical operation, we give you the following 
recommendations:

 

 

 

For this air conditioner we recommend a room size of up to 20 m² (50 m³) ! 

 

The minimum size of the room in which the unit is to be operated is at least 11m² ! 

 

Lock windows and doors. 

 

Avoid direct sunlight into the room through windows and doors. It is best to close the shutters or curtains 
during the day. 

 

Always keep the air filters of the air conditioner clean. 

 

Once you have reached the desired room temperature, reduce the operating strength of the air conditioner. 

 
 
Set-up and connection: 

1. connecting the exhaust hose for the warm air

 

 
 

    

                               

 

The mobile air conditioner generates warm exhaust air during cooling. This warm exhaust air must be discharged 

to the outside. You can either direct the warm exhaust air outside through a suitable hole (160 mm diameter) in the 

wall (similar to a kitchen extractor bonnet) or discharge it through a gap of an open window/door. 

Note: Depending on the given conditions, it may be advantageous to use the closure strip provided for this 

purpose. The closure strip is variably adjustable and can thus ensure that no air from outside gets inside. 

1.1. 

Connect the exhaust hose for the warm air to the rear exhaust duct of your air conditioner by first fitting the 

hose adapter (ring-shaped) to the unit and then screwing on the warm air hose clockwise. 

1.2. 

Attach the supplied adapter for the sealing strip to the other end of the exhaust air hose. 

1.3. 

If you have installed the closing strip at the window gap/door gap/wall, now insert the adapter into its 

intended recess. Alternatively, guide the adapter through the window gap/door gap to the outside so that 

the warm exhaust air can be blown out unhindered. 

 

 

 

 

 

 

Содержание WDH-FGA1075

Страница 1: ...per transport can sometimes occur despite careful instructions on the carton Therefore we ask you to let it stand upright for at least 4 hours before using it for the first time so that the refrigeran...

Страница 2: ...sary physical and mental capabilities to operate this unit without problems This air conditioner is only approved for indoor use Only qualified personnel or electricians are allowed to open the unit O...

Страница 3: ...ust air cold 6 air filter 7 condensation drain 8 mains plug compartment 9 air intake 10 air intake Accessories 11 adapter for connecting the warm air hose with the window slit shutter bar 12 exhaust a...

Страница 4: ...ng This warm exhaust air must be discharged to the outside You can either direct the warm exhaust air outside through a suitable hole 160 mm diameter in the wall similar to a kitchen extractor bonnet...

Страница 5: ...e extended from 30 cm to a maximum of 150 cm But for maximum effectiveness and economy we recommend the shortest possible length Warning The length of the exhaust air hose is specially adapted to the...

Страница 6: ...gnal light when fan operation is activated h Signal light during dehumidification operation i Signal light when heating mode is activated inactive on this unit type j Signal light when the water tank...

Страница 7: ...M Average operating strength C L Weak operating strength Note In automatic mode the operating strength is set automatically by the unit The operating level you have just selected is indicated by a sma...

Страница 8: ...es not included 9 Error display The air conditioner detects malfunctions and displays them in the unit s display panel If the display field shows E1 or E2 please contact your dealer 10 Other operating...

Страница 9: ...zontally Now the condensation water can drain out of the tank 4 If your drip tray is full but there is still water in the condensation tank simply put the rubber plug back on the drain hole and then e...

Страница 10: ...acent illustration Use the original carton to store the air conditioner Troubleshooting The unit does not switch on Check the mains plug and try a different socket Check if the house fuse has popped o...

Страница 11: ...930 watts Energy efficiency ratio EER 2 6 Unit type Cooling only Cooling type Air cooling Noise emission 65 dB A Voltage 220 240V 50Hz Max Power consumption 1 130 W 5 0 A Power consumption in operatin...

Страница 12: ...tage or non observance of the assembly instructions Completely or partially dismantled units Conformity The air conditioner has been tested and itself and or parts thereof have been manufactured under...

Отзывы: