Control of defrost in standard mode (CE=0)
Defrost start
Defrost will start if:
• The time programmed in parameter d0 has elapsed since the start of the last defrost.
• Press the
H
key for 3 seconds.
• By means of an external push-button (I10 / I11=5).
• Through the app or through AKONet.
Defrost completion
Defrost will complete if:
• The temperature programmed in parameter d4 has been reached in sensor 2. This requires a 2nd sensor
(l00=2) to be available, located in the evaporator.
• The time configured in parameter d1 has elapsed (maximum defrost duration).
• Press the
H
key for 5 seconds.
• By means of an external push-button (I10 / I20=5).
• Through the app or through AKONet.
S1
Max. d1
d9
d3
d0
d4
SP
SP+C1
F4
COLD REGULATION
COLD REGULATION
“DEF” MESSAGE
DRIP TIME
FAN START-UP DELAY
DEFROST
DEFROST