5.- Wiring
21
24
27
30
33
36
40
22
25
28
31
34
37
41
23
26
29
32
35
38
42
39
43
MODBUS
RS-485
ALARM
RELAY
S3
S2
S1
DI1
DI2
GND
Tr
Tr
NC
NO
C
8A
L
N
PE
FAN
230Vac
2.2 A
L N
L N
N
L
N
L
N
L
CRANKASE
HEATER
230Vac
70W
LIGHT
230Vac
460W
CONDENSING
UNIT
230Vac
11.5A
2 CV
DEFROST
RESISTANCE
230Vac
11A
2500W
1
The auxiliary relay output function (terminals 40 and 41) is configurable (See page. 23).
AUXILIARY
RELAY
1
ATTENTION:
Make sure to turn of the equipment's power supply before handling it, as different areas
may be energised.
IMPORTANT
Ÿ
The recommended currents and powers are the maximum working currents and powers.
Ÿ
The function of each probe depends on the "probe configuration" parameter (See page 11).
Ÿ
Remember that the control probe and registration probe should be configured separately if you
want to comply with EN12830.
6
POWER SUPPLY INPUT
10% -15%
50/60Hz ±3Hz
CONNECT ALL EARTH
CONNECTIONS IN
THIS TERMINAL
AUX.