Version : 2012.1
3
Operating Instructions
-EN-
1
Indicator light
(flashes to indicate that
the appliance is ready
for use)
2 230V ~ power cable
3 Earth connection
4
Fence connection
5 Fastening hole
a.) Installation
The fastening hole (5) is used for wall mounting. The appliance must be mounted against a perpendicular,
fireproof wall with the power cable at the bottom, see above figure. For outside installation the device must
also be protected against exposure to rain and direct sunlight.
b.) Functional description of the appliance
Put the appliance into service
without
fence and earth. If the indicator light (1) flashes at the pulse rate, the
appliance is ready for use.
If the indicator light (1) does not flash, check the supply voltage and/or the power cable. If no fault is found, the
appliance should be checked by a technician.
c.) Functional description with connected fence system ( fence + earth )
5. Connect fence system and earth
6. Insert 230V power cable
Indicator
light (1)
Function
Fence voltage
Remarks
3.
flashes
green
Fence and
earth OK
> 2500V
= min. requirement
Fence system OK!
(prerequisite: fence system not interrupted)
4.
flashes
red
Fault:
insufficent
earth
< 2500 V
= insufficient
Fault :
Voltage on earth electrode > 1000V
see fault finding in enclosed instruction manual (Figure 2, p. 5)
Fault:
Fence system
shorted to
earth
Fault condition: low fence voltage, no excessive voltage on earth
electrode
Measure voltage on fence: min. value: 2500V throughout the
fence
see fault finding in enclosed instruction manual (Figure 2, p. 5)
5.
does
not
flash
Appliance
NOK
See above: b.) Functional check of the appliance
If the indicator light flashes faster than approx. once per second, the appliance must be disconnected at once and
checked by a technician before it can be used again.
New function in accordance with EN 60335-2-76 A12: 2010
Following a delay time of 15 seconds this device delivers an output energy of no more than 5 joules.
With an increasing load the device increases its output energy after a delay time has lapsed and therefore automatically
adjusts the shock strength to the increased growth, weather conditions and fence status.
This equipment carries a 3-year warranty in accordance with our Warranty Terms & Conditions!
Please see the attached Operating Instructions for safety tips, earthing, commissioning, warranty terms and
conditions and potential sources of fault!
SERVICE Addresses:
Please contact your specialist dealer
Not suited for use in barns!