![AKM AKD4396-SBW Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/akm/akd4396-sbw/akd4396-sbw_manual_2886268003.webp)
[AKD4396-SBW]
<KM078103> 3 2011/03
Evaluation mode
1.
DIR(COAX) (default)
J1 is used for the evaluation using such as CD test disk. The DIR generates MCLK, BICK and LRCK SDATA from the
received data through BNC connector (J1). Setting of jumper is shown below.
COAX is recommended for an evaluation of the Sound quality.
JP1
OPT
COAX
BNC
(Default)
Figure 2
Jumper setting, when using DIR
2.
DIR(Optical Link)
PORT1 is used for the evaluation using such as CD test disk. The DIR generates MCLK, BICK and LRCK SDATA from the
received data through
optical connector (PORT2: TORX176).
Setting of jumper is shown below.
JP1
OPT
COAX
PORT2
Figure 3
Jumper setting, when using DIR
3.
All clocks are fed through the PORT1.
-R9, R12, R13, R14 : open
-R10, R15, R19, R20 : 100
Ω
or short (0
Ω)
DIP Switch setting
[SW2]: AK4113 setting
No. Pin
OFF
ON
Default
1 OCKS1
ON
2 OCKS0
AK4113 Master Clock setting
Refer to Table4
OFF
Table 2 SW2 setting
[SW3]: AK4396 setting
No. Pin
OFF
ON
Default
1
-
2
P/S
Serial mode (Note) Parallel
mode
ON
Note : When using the serial mode, R5 and R17 should be removed.
Table 3
SW3 setting