![AKM AKD4396-SBW Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/akm/akd4396-sbw/akd4396-sbw_manual_2886268012.webp)
[AKD4396-SBW]
<KM078103> 12 2011/03
Measurement Results
[Measurement condition]
•
Measurement unit
: Audio Precision System two Cascade (AP2)
•
MCLK
: 512fs (44.1kHz), 256fs (96kHz), 128fs (192kHz)
•
BICK
: 64fs
•
fs
: 44.1kHz, 96kHz, 192kHz
•
Bit
:
24bit
•
Power Supply
: AVDD= DVDD=5V
•
Interface
: Internal DIR (48kHz, 96kHz, 192kHz)
•
Temperature
: Room
fs=44.1kHz
Parameter
Input signal Measurement filter
Results
S/(N+D)
1kHz, 0dB
20kLPF
99.4 dB
DR
1kHz, -60dB 22kLPF, A-weighted
119.0 dB
S/N
“0” data
22kLPF, A-weighted
119.0 dB
fs=96kHz
Parameter
Input signal Measurement filter
Results
S/(N+D)
1kHz, 0dB
40kLPF
99.0 dB
DR
1kHz, -60dB
40kLPF
114.0 dB
DR
1kHz, -60dB 22kLPF, A-weighted
119.3 dB
S/N
“0” data
40kLPF
114.0 dB
S/N
“0” data
22kLPF, A-weighted
119.3 dB
fs=192kHz
Parameter
Input signal Measurement filter
Results
S/(N+D)
1kHz, 0dB
40kLPF
98.7 dB
DR
1kHz, -60dB
40kLPF
111.2 dB
DR
1kHz, -60dB 22kLPF, A-weighted
116.4 dB
S/N
“0” data
40kLPF
113.6 dB
S/N
“0” data
22kLPF, A-weighted
119.0 dB