69
g
Charging errors
No. 30: Timeout in the corresponding
charging phase or
Remedy:
-
Set Ah to correct value
-
Check for parallel consumers (car ra-
dio, etc.)
-
Battery temperature too high
No. 31: Too many Ah charged, too few Ah set
Remedy:
-
Set Ah to correct value
-
Check for parallel consumers (car radio, etc.)
-
Replace battery if it appears to be faulty
No. 32: Optional external temperature sensor has tripped due to undertemperature
Remedy:
-
Charge the battery in a more suitable area
No. 33: Optional external temperature sensor has tripped due to overtemperature
Remedy:
-
Allow battery to cool, or charge battery in a more suitable area
No. 34: Battery voltage set too high
Remedy:
-
Set the correct battery voltage
No. 37: Conservation charge current too high
Remedy:
-
Check for parallel consumers (car radio, etc.)
No. 50: Device output fuse defective
Remedy:
-
Contact After-Sales Service
No. 51: Secondary temperature out of range
Remedy:
-
Contact After-Sales Service