18
Model No: AC-S10HKX2
Version 1.0
7. SMART MODE OPERATION
When SMART air conditioning is selected, the operation mode and preset temperature are set
automatically according to the room temperature at starting operation.
The operation procedure of
cooling only
is as following.
Intake air temperature at
operation start
Over 26
℃
Below 26
℃
Preset temperature
26
℃
Intake air temperature minus 1.5
℃
Operation mode
COOLING
DRY
*The initial mode will be continued and independent upon the room temperature changing.
The operation procedure of
heat pump
is as following.
Intake air temperature at
operation start
Over 26
℃
21
℃
~ 26
℃
Below 21
℃
Preset temperature
26
℃
Intake air temperature at
operation start
22
℃
Operation mode
COOLING
DRY
HEATING
The initial mode will be continued and independent upon the room temperature changing.
If initial mode is selected, that mode is continued, independent upon the temperature changing.
The indoor fan motor speed is automatically determined by
Auto Fan Speed
. If you are not
satisfied with the auto fan speed, you can adjust the fan speed by pressing the FAN BUTTON.
8. AUTO FAN SPEED
When the Auto Fan Speed is selected in COOLING or HEATING operation, the indoor fan
motor speed is automatically controlled by the intake air temperature and the preset temperature.
The operation procedure of COOLING is as following.
Все каталоги и инструкции здесь:
http
:
//splitoff.ru/tehn-doc.html
Содержание AC-S10HKX2
Страница 27: ...27 Model No AC S10HKX2 Version 1 0 Все каталоги и инструкции здесь http splitoff ru tehn doc html ...
Страница 45: ...45 Model No AC S10HKX2 Version 1 0 Все каталоги и инструкции здесь http splitoff ru tehn doc html ...
Страница 48: ...48 Model No AC S10HKX2 Version 1 0 OUTDOOR UNIT Все каталоги и инструкции здесь http splitoff ru tehn doc html ...
Страница 51: ...51 Model No AC S10HKX2 Version 1 0 Outdoor Unit Все каталоги и инструкции здесь http splitoff ru tehn doc html ...