17
After Sales Support 1300 886 649
5.4 How to install
5.4.1 Installation of the housing
Step1
Remove the air conditioner from it's packaging, remove fixing screws and slide the
air conditioner out of it's housing (Refer to Installation Steps)
Step2
Prepare the hole in the wall so that the bottom of the housing is well supported,
the top has minimum clearance and the air inlet louvers have clearance as shown
below in options A and B. Holes from the outside through to the cavity should be
sealed. The housing should slope down towards the rear b about 5mm to allow
water formed during operation to drain.
Step3
Install the housing into the wall and secure. Ensure the foam seals are not damaged.
Flash, seal or fill gaps around the inside and outside to provide satisfactory
appearance and protection against the weather, insects and rodents.