34
After Sales Support 1300 886 649
Water drips from the unit.
Check whether the ambient humidity is too high.
Check whether the unit is correctly installed.
Check whether the foam of evaporator base is damaged.
Check whether the indoor outlet airflow foam is too wet, and louver drip.
Check whether the drain passage of evaporator is blocked. Replace if failed.
Check whether the air outlet foam install normally.
Fan motor speed can’t change.
Check the wiring.
Replace the PCB.
Check the capacitor of fan motor. Replace if failed.
Check the resistance of fan motor and replace the motor if failed.
Содержание MWF-18CRN1-QC1G
Страница 24: ...23 After Sales Support 1300 886 649 8 1 MWF 05CRN1 QC1G MWF 07CRN1 QC1G 8 2 MWF 07HRN1 QC1G 8 Wiring diagram ...
Страница 26: ...25 After Sales Support 1300 886 649 8 5 MWF 16HRN1 QC1G 8 6 MWF 18HRN1 QC1G ...
Страница 27: ...26 After Sales Support 1300 886 649 8 7 MWF 21CRN1 QC1G 8 8 MWF 21HRN1 QC1G ...
Страница 36: ...35 After Sales Support 1300 886 649 ...
Страница 37: ...36 After Sales Support 1300 886 649 Insufficient cooling ...
Страница 38: ...37 After Sales Support 1300 886 649 ...
Страница 39: ...38 After Sales Support 1300 886 649 11 Characteristic of temperature sensor ...