Version 3.11 Addendum

Page 3

MULTI-MACHINE CONNECTIONS

On the rear panel, you will find two BNC connectors, each with a terminator switch:

The AKAINET and SYNC IN/OUT connectors must both be connected as described in the
following sections to enable the multi-machine synchronisation function to be used.

Akainet (Ethernet) Connections

The AKAINET connectors on each DR16pro should be connected together to allow multi-
machine synchronisation messages to be passed from one machine to another. This should
be done using standard Ethernet BNC cables. These are chained between the AKNET BNC
connectors on each DR16pro using BNC ‘T’ connectors to link each cable where necessary.

If you are using an RE32 Remote Controller, this should also be connected to the AKAINET
bus as described in the RE32 manual.

Содержание DR16 pro

Страница 1: ...HARD DISK RECORDER Operator s Manual WARNING To prevent fire or shock hazard do not expose this appliance to rain or moisture 000306 Printed in Japan Version 3 11 Addendum...

Страница 2: ...particular purpose In no event will AKAI professional M I Corp be liable for direct or indirect damages arising from any defect in the software or its documentation Further AKAI professional M I Corp...

Страница 3: ...3 Akainet Ethernet Connections 3 Sync Connections 4 MULTI MACHINE SETUP 7 Set Machine IDs 7 Master Slave Selection 8 Save Settings To Flash 9 MULTI MACHINE OPERATION 10 Parameter settings 10 Using Di...

Страница 4: ...function allows multiple DR16pro machines to be accurately synchronised for playback and recording The system uses a combination of the AKAINET connections on each machine to pass synchronisation mes...

Страница 5: ...used Akainet Ethernet Connections The AKAINET connectors on each DR16pro should be connected together to allow multi machine synchronisation messages to be passed from one machine to another This sho...

Страница 6: ...imum of 185m of cable in the system between the first and last nodes There should be at least 0 5m of cable between each connection Sync Connections The SYNC IN OUT connectors on each DR16pro should b...

Страница 7: ...nised multi machine system comprising 4 machines would therefore be connected as follows The AKAINET chain provides the necessary transport control etc whilst the SYNC IN OUT connection maintains accu...

Страница 8: ...in the chain it should have termination switched on Of course you may have more or less machines in your system however many you have remember that termination must be switched ON on the first and la...

Страница 9: ...play will show SUB MENU 2 Press the 3 SETUP key on the numeric keypad 3 Use the JOG SHUTTLE control to select the AKAINET menu You will see a display similar to the following 4 Press the STORE ENT key...

Страница 10: ...select the AKAINET menu You will see a display similar to the following 4 Press the STORE ENT key A message such as MACHINE 01 will appear on the display showing the currently selected Machine ID numb...

Страница 11: ...settings on each machine The following procedure should be repeated on each DR16pro in the system 1 Press the SUB MENU key 2 Press the 3 SETUP key 3 Use the JOG SHUTTLE control to select the FLASH SA...

Страница 12: ...e Clock Source When operating with multi machine synchronisation the SYNC IN OUT connection on the DR16pro is used to transmit a special signal from the MASTER machine which is used as a sample clock...

Страница 13: ...a multi machine setup however the following configuration would be appropriate Here the MASTER DR16pro Machine ID1 is used as the clock master and all other devices in the system are slaved to it Mach...

Страница 14: ...The following is likely to be the most appropriate configuration if you are using an external digital mixer In this setup the master DR16Pro ID1 receives sample clock from the mixer s digital outputs...

Страница 15: ...m Check the MACHINE IDs to ensure that each DR16pro has been assigned a unique ID number from 1 to the number of machines in the system This message indicates there has been a problem synchronising th...

Страница 16: ...ess the 3 SETUP key on the numeric keypad 3 Use the JOG SHUTTLE control to select the O S LOAD function You will see a display similar to the following 4 Press the STORE ENT key The message SCSI ID 0...

Страница 17: ...y from 0 to 100 as the new operating system is being programmed WARNING Do not switch off the DR16pro while the Flash ROM is being erased or programmed If you do the DR16pro may not reboot when next p...

Страница 18: ...the TASCAM meter unit supplied with the IB D8TIF can not be installed in the DR16pro Selecting TDIF Audio Inputs 1 Press the DIGI key The DIGI key will light to show that the inputs from the IB D8TIF...

Страница 19: ...wing 3 Use the JOG wheel to select TDIF NORM 4 Use the SHUTTLE control to move the cursor to the right hand field Turn the JOG wheel to select SWAP This will assign tracks 9 16 to the 8 outputs from t...

Отзывы: