Maintenance

Check the operational capability of the detector regularly.

Clean the detector body from dust, spider web, and other contaminants as they appear. Use soft
dry napkin suitable for tech equipment.

Do not use any substances containing alcohol, acetone, gasoline, and other active solvents to clean the
detector.

The pre-installed battery ensures up to 7 years of autonomous operation (with the 5 minutes
ping interval by the hub). If the detector battery is low, the system noti es the user, and the LED
indicator smoothly lights up and goes off if a glass break is detected or the tamper is triggered.

Tech specs

Sensitive element

Electret microphone

Glass break detection distance

Up to 9 m

Microphone coverage angle

180°

Tamper protection

Yes

Frequency band

868.0 – 868.6 MHz or 868.7 – 869.2 MHz depending on the
region of sale

Compatibility

Operates with all Ajax 

,

Maximum RF output power

Up to 20 mW

Radio signal modulation

GFSK

Radio signal range

Up to 1,000 m (any obstacles absent)

Socket for connecting wire detectors

Yes, NC

Power supply

1 battery CR123A, 3 V

Battery life

Up to 7 years

Installation method

Indoors

Operating temperature range

From -10°С to +40°С

Operating humidity

Up to 75%

Overall dimensions

Ø 20 × 90 mm

Weight

30 g

Certi cation

Security Grade 2, Environmental Class II in conformity with
the requirements of EN 50131-1, EN 50131-2-7-1, EN 50131-
5-3

Complete Set

Warranty

Warranty for the “AJAX SYSTEMS MANUFACTURING” LIMITED LIABILITY COMPANY products is
valid for 2 years after the purchase and does not apply to the pre-installed battery.

If the device does not work correctly, you should  rst contact the support service — in half of the
cases, technical issues can be solved remotely!

Technical support: 

How long Ajax devices operate on batteries, and what affects this

Battery Replacement

hubs range extenders

ocBridge Plus uartBridge

1. GlassProtect

2. SmartBracket mounting panel

3. Battery CR123A (pre-installed)

4. Outside-mounted terminal clamp

5. Installation kit

6. Quick Start Guide

The full text of the warranty

User Agreement

[email protected]

Содержание GlassProtect

Страница 1: ...inciple GlassProtect uses a sensitive electret microphone to detect the sound of glass breaking consisting of a low frequency hit sound and high frequency crashing sound of glass shatters Such two stage glass break detection decreases the risk of false triggering GlassProtect detector does not react to the breaking of the lm covered glass shockproof sunscreen decorative or any other type of lm To ...

Страница 2: ...tions in the user manual of the respective device States Parameter Value Temperature Temperature of the detector measured on the processor and changes gradually Jeweller Signal Strength Signal strength between the hub and the detector Connection Connection status between the hub and the detector Battery Charge Battery level of the device Displayed as a percentage Lid The tamper state which reacts ...

Страница 3: ...activated when the glass break detected Activate the siren if an additional contact is open If active added to the system are activated in case of an external detector alarm Jeweller Signal Strength Test Switches the detector to the Jeweller signal strength test mode Detection Zone Test Switches the detector to the detection area test Attenuation Test Switches the detector to the signal fade test ...

Страница 4: ...etector Hit the glass with your st without breaking it If the detector catches a low frequency sound the LED blinks Simulate a high frequency glass shattering sound for 1 5 seconds after the rst hit with a special tool or hitting a glass with a metal object After recognizing the sound the detector switches off the LED indicator for a second To be triggered when the system is armed the detector nee...

Страница 5: ...e attachment panel the security system noti es you Connecting a Wired Detector A wired detector with an NC normally closed contact type can be connected to GlassProtect using the in built terminal clamp We recommend installing the wired detector at a distance no longer than 1 meter to GlassProtect Longer wire length increases the risk of its damage and reduces the quality of communication between ...

Страница 6: ...adio signal range Up to 1 000 m any obstacles absent Socket for connecting wire detectors Yes NC Power supply 1 battery CR123A 3 V Battery life Up to 7 years Installation method Indoors Operating temperature range From 10 С to 40 С Operating humidity Up to 75 Overall dimensions Ø 20 90 mm Weight 30 g Certi cation Security Grade 2 Environmental Class II in conformity with the requirements of EN 501...

Страница 7: ......

Отзывы: