background image

The system can also automatically deactivate devices
when the set number of alarms is exceeded or when the
recovery timer expires

User Guide

Opens the User Guide for detector

Unpair Device

Disconnects the detector from the hub and deletes its
settings

Indication

Event

Indication

Note

Turning on the detector

Lights up green for about one second

Detector connection to the 

,

 and 

Lights up continuously for a few
seconds

Alarm / tamper activation

Lights up green for about one second

Alarm is sent once in 5 seconds

Battery needs replacing

During the alarm, it slowly lights up
green and slowly goes out

Replacement of the detector battery
is described in the 

 manual

Functionality testing

The Ajax security system allows conducting tests for checking the functionality of connected
devices.

The tests do not start immediately but within a period of 36 seconds when using standard
settings. The test time start depends on the settings of the detector ping interval (the paragraph
on “Jeweller” settings in hub settings).

Detector functionality testing

Having de ned the location of the detector and having  xed the device with the bundled
adhesive tape, test the detection zone.

GlassProtect does not react to clapping!

Testing the detector

Hit the glass with your  st without breaking it. If the detector catches a low-frequency sound, the
LED blinks. Simulate a high-frequency glass shattering sound for 1.5 seconds after the  rst hit
with a special tool or hitting a glass with a metal object. After recognizing the sound, the
detector switches off the LED indicator for a second.

To be triggered when the system is armed, the detector needs to recognize sounds in the following order:
low-frequency sound (hit)  rstly, then high-frequency sound (glass shattering, shards). Otherwise, the alarm
will not go off.

Switch on/off all the appliances that usually operate in the room: generators, air conditioners,
etc. If this triggers the detector, try to change the sensitivity or relocate GlassProtect.

Use the sensitivity level, at which the detector correctly passes both test stages and does not
respond to any devices operating in the room.

Installing the device

Selecting the Location

In some cases, the household activity can cause false alarms

The location of GlassProtect depends on its remoteness from the hub, and obstacles hindering
the radio signal transmission: walls,  oors, large objects inside the room.

The device developed only for indoor use.

Check the Jeweller signal level at the installation location

Learn more about auto deactivation of
devices

hub

ocBridge Plus

uartBridge

Battery

Replacement

Jeweller Signal Strength Test

Detection Zone Test

Attenuation Test

Содержание GlassProtect

Страница 1: ...inciple GlassProtect uses a sensitive electret microphone to detect the sound of glass breaking consisting of a low frequency hit sound and high frequency crashing sound of glass shatters Such two stage glass break detection decreases the risk of false triggering GlassProtect detector does not react to the breaking of the lm covered glass shockproof sunscreen decorative or any other type of lm To ...

Страница 2: ...tions in the user manual of the respective device States Parameter Value Temperature Temperature of the detector measured on the processor and changes gradually Jeweller Signal Strength Signal strength between the hub and the detector Connection Connection status between the hub and the detector Battery Charge Battery level of the device Displayed as a percentage Lid The tamper state which reacts ...

Страница 3: ...activated when the glass break detected Activate the siren if an additional contact is open If active added to the system are activated in case of an external detector alarm Jeweller Signal Strength Test Switches the detector to the Jeweller signal strength test mode Detection Zone Test Switches the detector to the detection area test Attenuation Test Switches the detector to the signal fade test ...

Страница 4: ...etector Hit the glass with your st without breaking it If the detector catches a low frequency sound the LED blinks Simulate a high frequency glass shattering sound for 1 5 seconds after the rst hit with a special tool or hitting a glass with a metal object After recognizing the sound the detector switches off the LED indicator for a second To be triggered when the system is armed the detector nee...

Страница 5: ...e attachment panel the security system noti es you Connecting a Wired Detector A wired detector with an NC normally closed contact type can be connected to GlassProtect using the in built terminal clamp We recommend installing the wired detector at a distance no longer than 1 meter to GlassProtect Longer wire length increases the risk of its damage and reduces the quality of communication between ...

Страница 6: ...adio signal range Up to 1 000 m any obstacles absent Socket for connecting wire detectors Yes NC Power supply 1 battery CR123A 3 V Battery life Up to 7 years Installation method Indoors Operating temperature range From 10 С to 40 С Operating humidity Up to 75 Overall dimensions Ø 20 90 mm Weight 30 g Certi cation Security Grade 2 Environmental Class II in conformity with the requirements of EN 501...

Страница 7: ......

Отзывы: