background image

others wired detectors.

The type of alarm is indicated in the settings of the Transmitter. The text of
noti�cations about alarms and events of the connected device, as well as event
codes transmitted to the central monitoring panel of the security company (CMS)
depend on the selected type.

A total of 5 types of devices are available:

Type

Icon

Intrusion alarm

Fire alarm

Medical alarm

Panic button

Содержание 10306

Страница 1: ...rometer which protects it from dismounting It runs on batteries and can supply power to the connected detector Transmitter operates within the Ajax security system by connecting via the protected prot...

Страница 2: ...integration module receives information about alarms and tamper activation through the wires connected to the clamps Transmitter can be used to connect panic and medical buttons indoor and outdoor mo...

Страница 3: ...t of noti cations about alarms and events of the connected device as well as event codes transmitted to the central monitoring panel of the security company CMS depend on the selected type A total of...

Страница 4: ...ng the hub instruction recommendations install the on your smartphone Create an account add the hub to the application and create at least one room Ajax application 2 Go to the Ajax application 3 Swit...

Страница 5: ...ice If the connection to the Ajax hub failed the Transmitter will switch off after 6 seconds You may repeat the connection attempt then The Transmitter connected to the hub will appear in the list of...

Страница 6: ...atus of the device temporary deactivation function How battery charge is displayed in Ajax apps No the device operates normally and transmits all events Lid only the hub administrator has disabled not...

Страница 7: ...r Contact Status Selection of the external detector normal status External Detector Type Selection of the external detector type Tamper status Selection of the normal tamper mod for an external detect...

Страница 8: ...the Transmitter to provide an alarm in the event of device movement Detector Power Supply Turning the power on in 3 3 V external detector Arm in Night Mode If active the device will switch to armed mo...

Страница 9: ...n be normally closed or normally open The type mode of the external detector that can be bistable or pulse The tamper mode which can be normally closed or normally open The accelerometer triggered ala...

Страница 10: ...r 1 minute with an interval of 1 second then blinks 3 times rapidly and automatically switches OFF The Module has received alarm tamper signal The LED lights up for 1 second Batteries are discharged S...

Страница 11: ...itter should be encased inside the wired detector case The Module requires a space with the following minimum dimensions 110 41 24 mm If the installation of the Transmitter within the detector case is...

Страница 12: ...not connect external power to the Transmitter s power outputs This may damage the device 2 Secure the Transmitter in the case Plastic bars are included in the installation kit It is recommendable to i...

Страница 13: ...tput power Up to 20 mW Modulation GFSK Communication range Up to 1 600 m any obstacles absent Ping interval for the connection with the receiver 12 300 sec Operating temperature From 25 to 50 Operatin...

Страница 14: ...in half of the cases technical issues can be solved remotely Technical support The full text of the warranty User Agreement support ajax systems...