SERVICING NOTICES ON CHECKING
1. KEEP THE NOTICES
2. AVOID AN ELECTRIC SHOCK
As for the places which need special attentions, they are
indicated with the labels or seals on the cabinet, chassis
and parts. Make sure to keep the indications and notices
in the operation manual.
There is a high voltage part inside. Avoid an electric
shock while the electric current is flowing.
3. USE THE DESIGNATED PARTS
The parts in this equipment have the specific
characters of incombustibility and withstand voltage for
safety. Therefore, the part which is replaced should be
used the part which has the same character.
Especially as to the important parts for safety which is
indicated in the circuit diagram or the table of parts as
a mark, the designated parts must be used.
6. AVOID AN X-RAY
Safety is secured against an X-ray by considering about
the cathode-ray tube and the high voltage
peripheral circuit, etc.
Therefore, when repairing the high voltage peripheral
circuit, use the designated parts and make sure not
modify the circuit.
Repairing except indicates causes rising of high
voltage, and it emits an X-ray from the cathode-ray tube.
4. PUT PARTS AND WIRES IN THE ORIGINAL
POSITION AFTER ASSEMBLING OR WIRING
There are parts which use the insulation material such
as a tube or tape for safety, or which are assembled in
the condition that these do not contact with the printed
board. The inside wiring is designed not to get closer to
the pyrogenic parts and high voltage parts. Therefore,
put these parts in the original positions.
5. TAKE CARE TO DEAL WITH THE
CATHODE-RAY TUBE
In the condition that an explosion-proof cathode-ray
tube is set in this equipment, safety is secured against
implosion. However, when removing it or serving from
backward, it is dangerous to give a shock. Take
enough care to deal with it.
PERFORM A SAFETY CHECK AFTER
SERVICING
7.
Confirm that the screws, parts and wiring which were
removed in order to service are put in the original
positions, or whether there are the portions which are
deteriorated around the serviced places serviced or not.
Check the insulation between the antenna terminal or
external metal and the AC cord plug blades. And be sure
the safety of that.
(INSULATION CHECK PROCEDURE)
1.
2.
3.
4.
Unplug the plug from the AC outlet.
Remove the antenna terminal on TV and turn on the
TV.
Insulation resistance between the cord plug terminals
and the eternal exposure metal [Note 2] should be
more than 1M ohm by using the 500V insulation resis-
tance meter [Note 1].
If the insulation resistance is less than 1M ohm, the
inspection repair should be required.
[Note 1]
If you have not the 500V insulation resistance meter,
use a Tester.
[Note 2]
External exposure metal: Antenna terminal
Earphone jack
A-2