CHLORINE GENERATOR FUNCTIONS
6
5
1
2 3 4
7
8
9
10
1. Status Light 1 – High Salt
If the light is on see Troubleshooting guide,
page 17.
2. Status Light 2 – Cell Off / Salt Low
If the light is on or fl ashing see
Troubleshooting guide, page 17.
3. Status Light 3 – Power On /
No Water Flow
If light is steady, unit is powered. If the light
is fl ashing, see Troubleshooting guide,
page 17.
4. Status Light 4 – Overload / Normal
Operation
When light is ON/Steady and machine
is beeping, the chlorine generator power
supply is on standby due to failure. Contact
manufacturer for service.
When fl ashing, machine is working in
reverse cycle (normal operation).
5. Chlorine Controller
Turn clockwise to increase the chlorine
output and anti-clockwise to reduce the
chlorine output.
(Note: When chlorine output lights are off
and ‘power on (light 3)’ and ‘cell off (light 2)’
lights are on, chlorine production is in
standby mode).
6. Chlorine Output Indicators
Each light on represents 10% of chlorine
output (e.g. 5 lights on = 50% output).
7. Time Clock (Timer models (RP10TH
and RP10QTH) only)
See page 12 for operation.
8. Circuit Breaker
If tripped, refer to Troubleshooting guide
on page 17.
9. Time Clock Bypass (Timer models
(RP10TH and RP10QTH) only)
See page 13 for operation.
10. Pump Outlet Socket
The three-pin plug supplying power to the
pump is connected here.
Fig. 1