TIE ALL WIRING TO INSURE NO CONTACT

 

 

WITH THE HEATER OR ANY SHARP EDGES. 

 

KEEP IN MIND THAT HIGH VELOCITY AIR 

 

WILL BE ENCOUNTERED IN THIS AREA. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

    FIGURE 4 

 
 
 
 

 
 
                 

  FIGURE 3 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

FIGURE 5 

 
 
 
 

INSTALL AIR GRILLE ASSEMBLY 

 

1. 

Temporarily remove the air grille assembly filter 

 

door.  A quarter-turn of the fastener will disengage 

 

the door.  Attach the air grille frame to the mount 

 

frame with 3 screws as shown in Figure 1 – use 3/4" 

 

screws.  Adjust as desired to insure that all foam parts 

 

are within the grille perimeter, and secure the corners 

 

 

of the grille to the ceiling.  These 4 corner screws are 

 

not provided.  Check all fits to insure that a 

 

reasonably air tight seal exists to separate unit supply 

 

air from unit return air.  Re-install the filter door. 

 
2. 

Installation is now complete. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Drain Pan

Basepan

Ş

 

Содержание 8330 series

Страница 1: ...sion INSTALLATION INSTRUCTIONS FOR 8330 63 3 4 COOL ONLY A C 8330 635 HEAT READY A C 8530 63 HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY DESIGNED AND MANUFACTURED BY THE MAKERS OF COLEMAN MACH...

Страница 2: ...uipment in violation of state codes may create a hazard and may ruin the equipment WARNING SHOCK HAZARD To prevent the possibility of severe personal injury or equipment damage due to electrical shock...

Страница 3: ...The low temperature probe monitors the temperature of the air conditioner evaporator coil When the temperature of the evaporator coil drops below 28 degrees F the switch will open stopping compressor...

Страница 4: ...ow and system performance 3 Where ducting secures to the ceiling plenum maximum width is 8 inches 4 All field fabricated cold air supply ducting must be insulated and must have a vapor barrier IMPORTA...

Страница 5: ...sirable to provide 12 volt control power from the battery side of the converter These precautions should prevent control problems A Route the thermostat 12 VDC supply wiring from the power source to t...

Страница 6: ...Protection Device rated higher than the minimum required see upper unit nameplate Follow all local and NEC National Electrical Code for proper sizing of wire AWG based on Overcurrent Protection Devic...

Страница 7: ...ply wiring previously routed into the frame of the roof opening through the strain relief atop the electrical box and into the high voltage wiring area DANGER WHEN USING NON METALLIC SHEATH SUPPLY CAB...

Страница 8: ...iling plenum electrical box These low voltage ceiling plenum designations complete the following circuits B 12 VDC for all relay coils Y 12 VDC for compressor relay coil GH 12 VDC for hi fan relay coi...

Страница 9: ...r will disengage the door Attach the air grille frame to the mount frame with 3 screws as shown in Figure 1 use 3 4 screws Adjust as desired to insure that all foam parts are within the grille perimet...