background image

 

2

TABLE OF CONTENTS

 

 

 

Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

 

Package Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

 

General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  3 

 

Ceiling Plenum Installation Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . .  3 

 

Supply Ducting and Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   4 

 

Routing Thermostat Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5 

 

Routing 115 VAC Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  6 

 

Ceiling Plenum Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  6 

 

Connect 115 VAC Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  7 

 

Connect Thermostat Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  8 

 

Install Air Grille Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  9 

 

WARNINGS 

 

IMPORTANT NOTICE 

 

These instructions are for the use of qualified individuals 
specially trained and experienced in installation of this type 
equipment and related system components. 
 
Installation and service personnel are required by some states 
to be licensed.  PERSONS NOT QUALIFIED SHALL NOT 
SERVICE THIS EQUIPMENT. 
 

WARNING 

 

Improper installation may damage equipment, can create a 
hazard and will void the warranty. 
 
The use of components not tested in combination with these 
units will void the warranty, may make the equipment in 
violation of state codes, may create a hazard and may ruin the 
equipment. 

WARNING – SHOCK HAZARD 

 

To prevent the possibility of severe personal injury or 
equipment damage due to electrical shock, always be sure the 
electrical power to the appliance is disconnected during 
installation. 
 

CAREFULLY FOLLOW ALL INSTRUCTIONS AND 
WARNINGS IN THIS BOOKLET TO AVOID DAMAGE 
TO THE EQUIPMENT, PERSONAL INJURY OR FIRE. 
 

NOTE 

 

 

The words “Shall” or “Must” indicate a 

 

requirement which is essential to 

 

satisfactory and safe product performance. 

 
 

The words “Should” or “May” indicate a 

 

recommendation which is not essential 

 

and not required but which may be useful 

 

or helpful. 

 

PACKAGE CONTENTS 

 

1) 

Wirebox Assembly 

 
1) 

Duct Divider Board – Some models do not have 

 

Divider Boards (boards are provided bulk packed) 

 
1) 

Insulated Duct Locator Plate 

 
1) 

Air Grille Assembly 

 
1) 

Installation Instructions 

 
  

1) 

Mount Frame 

 
1) 

Small Parts Package Consisting Of: 

 

4)

 

Bolts 

4)

 

Screws – 3/8” Length 

1)

 

Strain Relief 

2)

 

Metal Wing Nuts 

3)

 

Wire Nuts 

3)

 

        Screws – 3/4" Length 

1) 

Evaporator Freeze Sensor 

 
 
 
 
 

Содержание 8330 series

Страница 1: ...sion INSTALLATION INSTRUCTIONS FOR 8330 63 3 4 COOL ONLY A C 8330 635 HEAT READY A C 8530 63 HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY DESIGNED AND MANUFACTURED BY THE MAKERS OF COLEMAN MACH...

Страница 2: ...uipment in violation of state codes may create a hazard and may ruin the equipment WARNING SHOCK HAZARD To prevent the possibility of severe personal injury or equipment damage due to electrical shock...

Страница 3: ...The low temperature probe monitors the temperature of the air conditioner evaporator coil When the temperature of the evaporator coil drops below 28 degrees F the switch will open stopping compressor...

Страница 4: ...ow and system performance 3 Where ducting secures to the ceiling plenum maximum width is 8 inches 4 All field fabricated cold air supply ducting must be insulated and must have a vapor barrier IMPORTA...

Страница 5: ...sirable to provide 12 volt control power from the battery side of the converter These precautions should prevent control problems A Route the thermostat 12 VDC supply wiring from the power source to t...

Страница 6: ...Protection Device rated higher than the minimum required see upper unit nameplate Follow all local and NEC National Electrical Code for proper sizing of wire AWG based on Overcurrent Protection Devic...

Страница 7: ...ply wiring previously routed into the frame of the roof opening through the strain relief atop the electrical box and into the high voltage wiring area DANGER WHEN USING NON METALLIC SHEATH SUPPLY CAB...

Страница 8: ...iling plenum electrical box These low voltage ceiling plenum designations complete the following circuits B 12 VDC for all relay coils Y 12 VDC for compressor relay coil GH 12 VDC for hi fan relay coi...

Страница 9: ...r will disengage the door Attach the air grille frame to the mount frame with 3 screws as shown in Figure 1 use 3 4 screws Adjust as desired to insure that all foam parts are within the grille perimet...

Страница 10: ...10 Airxcel Inc RV Products Division P O Box 4020 Wichita KS 67204 Web www rvcomfort com Support www rvpsupport airxcel com Sales www rvpsales airxcel com 1976J307 8 13 PP...

Отзывы: