GENERAL INFORMATION 

 

The flush mount ceiling plenum is designed for application in 
systems that utilize field fabricated (OEM supplied) cold air 
ducting.  The ducting must be routed through the ceiling 
cavity (between the interior ceiling and roof).  Ducting 
specifications are given in the section labeled “Supply Ducting 
and Registers”. 
 
This system utilizes a single, non-ducted centrally located 
return air opening.  The return air opening is contained within 
the ceiling plenum.  The ceiling plenum must be located 
directly below the roof opening used for mounting the roof top 
unit. 
 
All manual controls have been removed from the ceiling 
plenum.  They have been replaced with control relays.  The 
relays are mounted in the electrical box of the ceiling plenum.  
The relays contain 12 VDC coils (which are energized by a 
wall mounted thermostat), with contacts that control the 115 
VAC used to power the roof top unit. 
 
All air conditioning functions are controlled by the low 
voltage wall mounted thermostat.  The thermostat controls a 
12 VDC electrical circuit which is used to energize the relays 
in the ceiling plenum.  The thermostats that Airxcel, Inc. 
provides for the system are combination (Heat/Cool) 
thermostats.  These thermostats are capable of operating both 
the roof top air conditioner and any furnace with a 12 VDC 
control circuit of 1 amp or less (continuous current). 

All air conditioning equipment is subject to freeze up when 
evaporator air flow is sufficiently reduced.  Ducting of any 
length creates potential for reduced evaporator air flow and 
system freeze-up.  To protect both the installer and Airxcel, 
Inc. from conditions that promote reduced air flow and system 
freeze-up, Airxcel, Inc. has equipped the ceiling plenum 
compressor control circuit with a low temperature probe.  The 
low temperature probe monitors the temperature of the air 
conditioner evaporator coil.  When the temperature of the 
evaporator coil drops below 28 degrees F, the switch will 
open, stopping compressor operation.  Compressor operation 
will resume once the evaporator warms to 55 degrees F. 
 

IMPORTANT 

 

The low temperature sensor is part of the ceiling plenum 
electrical circuit.  The probe must be inserted into the 
evaporator coil of the roof top unit by the installer when 
bolting the ceiling plenum to the roof top unit. 
 

The 8330 series ceiling assemblies will mount to and operate 
all 47200, 48200 or 49200 series roof top air conditioners. 
 
The 8530 series ceiling assemblies will mount to and operate 
all 47000, 48000 or 49000 series roof top heat pumps. 

 

CEILING PLENUM INSTALLATION REQUIREMENT 

 

1. 

The ceiling plenum must be installed under the roof 

 

opening. 

 
 

The ceiling plenum bolts below the roof top unit. 

 

Compression of the framed ceiling cavity between 

 

the roof top unit and the ceiling plenum is what holds 

 

both components in place. 

 
2. 

Ceiling cavity depth (the measurement from the 

 

ceiling to the roof – maximum 6”). 

 
3. 

The 115 VAC service for the roof top unit must be 

 

routed into the ceiling plenum.  To prevent wire 

 

pinching and to promote ease of installation, 

 

allowances must be made for routing the 115 VAC 

 

supply wiring into the front of the roof opening. 

4. 

Thermostat wiring must be run from the wall 

 

thermostat mounting location to the wirebox low 

 

voltage terminals.  To prevent wire pinching and to 

 

promote ease of installation, allowances must be 

 

made for routing the low voltage wiring into the  

 

front of the opening. 

 
5. 

The wirebox has a 9 pin receptacle extending from 

 

the front.  This mates with the roof unit 115 volt 

 

electrical conduit.  When making this connection, 

 

verify that the plugs are properly aligned and have 

 

snapped together securely. 

 
6. 

A low voltage terminal strip on the front of the box 

 

connects to the thermostat wires.  The wires attach by 

 

1/4" quick connects. 

 
 
 
 
 
 
 
 
 
 

Содержание 8330 series

Страница 1: ...sion INSTALLATION INSTRUCTIONS FOR 8330 63 3 4 COOL ONLY A C 8330 635 HEAT READY A C 8530 63 HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY DESIGNED AND MANUFACTURED BY THE MAKERS OF COLEMAN MACH...

Страница 2: ...uipment in violation of state codes may create a hazard and may ruin the equipment WARNING SHOCK HAZARD To prevent the possibility of severe personal injury or equipment damage due to electrical shock...

Страница 3: ...The low temperature probe monitors the temperature of the air conditioner evaporator coil When the temperature of the evaporator coil drops below 28 degrees F the switch will open stopping compressor...

Страница 4: ...ow and system performance 3 Where ducting secures to the ceiling plenum maximum width is 8 inches 4 All field fabricated cold air supply ducting must be insulated and must have a vapor barrier IMPORTA...

Страница 5: ...sirable to provide 12 volt control power from the battery side of the converter These precautions should prevent control problems A Route the thermostat 12 VDC supply wiring from the power source to t...

Страница 6: ...Protection Device rated higher than the minimum required see upper unit nameplate Follow all local and NEC National Electrical Code for proper sizing of wire AWG based on Overcurrent Protection Devic...

Страница 7: ...ply wiring previously routed into the frame of the roof opening through the strain relief atop the electrical box and into the high voltage wiring area DANGER WHEN USING NON METALLIC SHEATH SUPPLY CAB...

Страница 8: ...iling plenum electrical box These low voltage ceiling plenum designations complete the following circuits B 12 VDC for all relay coils Y 12 VDC for compressor relay coil GH 12 VDC for hi fan relay coi...

Страница 9: ...r will disengage the door Attach the air grille frame to the mount frame with 3 screws as shown in Figure 1 use 3 4 screws Adjust as desired to insure that all foam parts are within the grille perimet...

Страница 10: ...10 Airxcel Inc RV Products Division P O Box 4020 Wichita KS 67204 Web www rvcomfort com Support www rvpsupport airxcel com Sales www rvpsales airxcel com 1976J307 8 13 PP...

Отзывы: