7

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

FIGURE 2 

 
 

CONNECT 115 VAC WIRING 

 

1. 

         WARNING – SHOCK HAZARD 

 
 

To prevent the possibility of severe personal 

 

injury or equipment damage due to electrical 

 

shock, always be sure the electrical power is 

 

disconnected or off before beginning  

 

installation. 

 

2. 

Complying with the “Danger” notice below, bring the 

 

115 VAC supply wiring previously routed into the 

 

frame of the roof opening, through the strain relief 

 

atop the electrical box and into the high voltage 

 

wiring area. 

DANGER 

 

 

WHEN USING NON-METALLIC SHEATH 

 

SUPPLY CABLES (ROMEX, ETC.), STRIP 

 

SHEATH BACK TO EXPOSE 4-6 INCHES 

 

OF THE SUPPLY LEADS.  STRIP THE 

 

INDIVIDUAL WIRE LEAD ENDS FOR  

 

WIRE CONNECTION (ABOUT 3/4" BARE 

 

WIRE).  INSERT STRAIN RELIEF INTO 

 

ELECTRICAL BOX.  INSERT THE 

 

SUPPLY WIRES THROUGH THE STRAIN 

 

RELIEF. 

 

(ON SOME UNITS, THERE WILL
BE MACHINE SCREWS AT
THESE LOCATIONS)

-

Содержание 8330 series

Страница 1: ...sion INSTALLATION INSTRUCTIONS FOR 8330 63 3 4 COOL ONLY A C 8330 635 HEAT READY A C 8530 63 HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY DESIGNED AND MANUFACTURED BY THE MAKERS OF COLEMAN MACH...

Страница 2: ...uipment in violation of state codes may create a hazard and may ruin the equipment WARNING SHOCK HAZARD To prevent the possibility of severe personal injury or equipment damage due to electrical shock...

Страница 3: ...The low temperature probe monitors the temperature of the air conditioner evaporator coil When the temperature of the evaporator coil drops below 28 degrees F the switch will open stopping compressor...

Страница 4: ...ow and system performance 3 Where ducting secures to the ceiling plenum maximum width is 8 inches 4 All field fabricated cold air supply ducting must be insulated and must have a vapor barrier IMPORTA...

Страница 5: ...sirable to provide 12 volt control power from the battery side of the converter These precautions should prevent control problems A Route the thermostat 12 VDC supply wiring from the power source to t...

Страница 6: ...Protection Device rated higher than the minimum required see upper unit nameplate Follow all local and NEC National Electrical Code for proper sizing of wire AWG based on Overcurrent Protection Devic...

Страница 7: ...ply wiring previously routed into the frame of the roof opening through the strain relief atop the electrical box and into the high voltage wiring area DANGER WHEN USING NON METALLIC SHEATH SUPPLY CAB...

Страница 8: ...iling plenum electrical box These low voltage ceiling plenum designations complete the following circuits B 12 VDC for all relay coils Y 12 VDC for compressor relay coil GH 12 VDC for hi fan relay coi...

Страница 9: ...r will disengage the door Attach the air grille frame to the mount frame with 3 screws as shown in Figure 1 use 3 4 screws Adjust as desired to insure that all foam parts are within the grille perimet...

Страница 10: ...10 Airxcel Inc RV Products Division P O Box 4020 Wichita KS 67204 Web www rvcomfort com Support www rvpsupport airxcel com Sales www rvpsales airxcel com 1976J307 8 13 PP...

Отзывы: