2-1
PRODUCT DATA SHEET
SM DUO38I 1-A.2 GB
2.
PRODUCT DATA SHEET
2.1
Outdoor Unit DUO 38 DCI / WDI Specifications.
Model Indoor Unit
WDI 7 9 12
Model Outdoor Unit
DCI DUO 38 R410A
Installation Method of Pipe
Flared
Characteristics
Units
Cooling
Heating
Capacity
(4)
)
Btu/hr
13300(4090-18750)
15350(4090-21140)
kW
3.90(
1.50
-5.50)
4.50(1.20-6.20)
Power input
(4)
kW
1.1(0.45-1.80)
1.24(0.45-1.80)
EER (Cooling) or COP(Heating)
(4)
W/W
3.55 3.61
Energy efficiency class
A
A
Power supply
V/Ph/Hz
220-240V/Single/50/60Hz
Rated current
A
4.8
5.4
Starting current
A
10.5
Circuit breaker rating
A
15
OUTDOOR
Refrigerant control
EEV
Compressor type,model
Single Rotary DC Inverter,Panasonic
5RS102XAB
Fan type & quantity
Propeller(direct) x 1
Fan speeds
H/L
RPM
920/500
Air flow
H/L
m3/hr
2160
Sound power level
H/L
dB(A)
62
63
Sound pressure
level
(3)
H/L
dB(A)
52
53
Dimensions
WxHxD
mm
795*290*610
Weight
kg
38
Package dimensions
WxHxD
mm
945*395*655
Packaged weight
kg
40
Units per pallet
Units
9 units per pallet
Stacking height
units
3 levels
Refrigerant type
R410A
Refrigerant chargless distance
kg/m
1.2/7.5
Additional charge per 1 meter
g/m
No need
Connections
between units
Liquid line
In.(mm)
1/4"(6.35)
Suction line
In.(mm)
3/8"(9.53)
Max.tubing length
m.
Max.30
Max.height difference
m.
Max. 10
Operation control type
Remote control
Heating elements
kW
Others
(1)Airflow in ducted units;at nominal external static pressure.
(2)Sound power in ducted units is measured at air discharge.
(3)Sound pressure level measured at 1-meter distance from unit.
(4)Rating conditions in accordance to ISO 5151 and ISO 13253 (for ducted units)
.