11-13
CONTROL SYSTEM
SM DUO38I 1-A.2 GB
11.21 Jumper
Settings
11.21.1
Indoor Unit Controller
0 = Open Jumper (disconnect jumper).
1 = Close Jumper (connect jumper).
Self test Jumper – J1
OPERATION
J1
SELF-TEST
1
NORMAL
0
Compensation Jumper – J2
Model
J2 (Default)
Compensation
Wall Mounted
0
Activated
Floor/Ceiling
1
Deactivated
Ducted/cassette
1
Activated
Family selection Jumper – J3, J4 and J5
Family
J5
J4
J3
Reserved
Reserved
Reserved
Wall Mounted (WNG/FLO)
Floor/Ceiling (PXD)
Reserved
Ducted (LS)
Cassette (K)
0
0
0
0
0
1
0
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1 1
IDU Model
Jumper Setting
J8
J7
J6
J5
J4
J3
WNG25
0
0
0
0
1
1
WNG35
0
1
0
0
1
1
WNG50
0
0
1
0
0
0
WNG60
0
1
1
0
0
0
WNG80
0
0
1
0
0
1
PXD25
0
0
0
1
0
0
PXD35
0
1
0
1
0
0
PXD50
1
0
0
1
0
0
K25
0
0
0
1
1
1
K35
0
1
0
1
1
1
K50
1
0
0
1
1
1
LS35
0
1
0
1
1
0
For wall mounted units Jumpers j7, j8 can be configured by service. All other jumpers on
the above table are factory default (cannot be changed by service).
For unit types as Cassettes, floor ceiling, and ducted, jumpers are set by a model plug.