Filter access

ACTIVE CHARCOAL FILTER

- An active charcoal filter and its support are

supplied as accessories with your product.
(1 per filter)

- In order to optimise air filtration, you can

install it as follows.

MAINTENANCE AND REPAIR

BEFORE UNDERTAKING MAINTENANCE
OPERATIONS, MAKE SURE THAT THE AIR
CONDITIONER IS DISCONNECTED FROM
THE MAINS.

Cleaning of air filter

Your air conditioner has an air filter clogging

indicator light. When this indicator light F
comes on, the filter must be cleaned.

- To remove the filter, pull the inlet grid forward

and press the filters slightly downwards to
unclip them.

- Reset the unit by pressing the Reset button.

The filter indicator light F goes out.

Do not operate the air
conditioner without the filter !

Cleaning of the air conditioner

- Rub the inside of the unit with a soft, dry

cloth.

- Do not use hot water or volatile detergents,

which could damage the face of the air
conditioner.

Precautions to be taken

- Check that there are no obstacles preventing

the flow of inlet air and pulsed air, on both
the indoor and outdoor units.

- Check that the air conditioner is correctly

connected.

Protection of the electronic system

- The indoor unit and the remote control must

not be located less than one metre from a
television set, a radio or any other electrical
appliance, in order to avoid interference.

- Protect the unit against direct sunlight.

Replacement of the remote control
batteries

- Remove the batteries from the remote

control unit via the rear flap.

- Fit two new 1.5 V type AAA dry cell batte-

ries.

MANUAL MENU

Содержание SX 12 RCC

Страница 1: ...LATION INSTRUCTION TH 3990012 06 Read this instruction sheet carefully before installing retain it safely for future reference SX 16 RCC 18 RCC 24 RCC 30 RCC Read this instruction sheet carefully befo...

Страница 2: ...SX Split system for wall ceiling mounting MANUAL MENU...

Страница 3: ...with the same circuit WARNING Cutoff power supply before starting to work on the appliance The manufacturer declines any responsibility and the warranty becomes void if these instructions are not res...

Страница 4: ...te distance between mounting holes 1 sensor connecting cable 1 active charcoal filter and its support SUMMARY DESCRIPTION Dimensions of Indoor Units 4 Dimensions of Outdoor Units 5 INSTALLATION Locati...

Страница 5: ...5 630 A MODEL 12 16 18 A 820mm MODEL 24 30 A 1200mm DIMENSIONS OF INDOOR UNIT SX Split system for wall ceiling mounting MANUAL MENU...

Страница 6: ...BE FLARED LIQUID TUBE FLARED VALVE CONNECTIONS AIR INTAKE AIR OUTLET 237 50 100 MIN WALL MINIMUM CLEARANCE 800 MIN WALL WALL 100 400 MIN WALL 500 MIN FROM TOP 760 544 472 58 48 15 300 325 370 WIRING C...

Страница 7: ...ort of the SX using the installation template supplied with the unit The cut outs for the unit are shown on this template Reminder of MINIMUM clearances to be provided Coolant connections can be made...

Страница 8: ...r determining the outlet for the condensate evacuation LH RH rear make sure that the wall mounting is installed with a slope which favours this evacuation Secure the wall support with 4 screws not sup...

Страница 9: ...ON OF THE OUTDOOR UNIT Minimum clearance to respect in mm Almohadillas de montaje x 4 Wall bracket not supplied CAUTION If the heat pump outdoor unit is installed in an area where the outdoor temperat...

Страница 10: ...Insulation sleeve The indoor unit may be installed above or below the unit The flare couplings are available as accessories in standard lengths of 2 5 5 and 8 m The pipes are delivered coiled and equ...

Страница 11: ...tubing on the wall support before installing the unit using the template supplied Place the tube locating template on the wall support INSTALLATION OF TUBING ON WALL SUPPORT After choosing your coola...

Страница 12: ...lamps provided Remove the tubing template you can now install your unit on its support NOTE output to the rear The slanted hole prevents condensates or rain from entering the unit Fit a Dia 70 mm slee...

Страница 13: ...RH side panels Screws FOR THE INTAKE GRID 1 Pull the grid forwards 2 Remove the two end screws 3 Unscrew the central screw but do not remove it completely 4 Unhook the grid FORTHESIDEPANELS 5 Remove...

Страница 14: ...the diagram below for installation of the SX Ceiling mounting refer to the NOTE below Wall mounted For ceiling mounting install the two clamp screws provided for the unit on the support Ceiling mounte...

Страница 15: ...the case of a connection to the wastewater system 2 5 cm m slope An S bend must be installed on the evacuation duct below the level of the recovery tray of the unit Provide insulation for the evacuati...

Страница 16: ...95 Nm 2 Connect the vacuum pump with the flare coupling of the outdoor unit equipped with a process valve 3 Start the vacuum pump and check that the needle of the indicator goes down to 0 2 mm Hg The...

Страница 17: ...4 N 3 V 0 3 2 t i n u e d i s t u o n i e g r a h C d e g r a h c y r o t c a f m 4 r o f C G p m u p t a e H e b o t e g r a h c 2 2 R e t i s e h t n o d e d d a l e d o m p m u p t a e H COOLING SP...

Страница 18: ...5 m 1 2 s r g 5 5 2 s r g 0 6 5 m 2 2 s r g 0 7 2 s r g 0 0 6 m 3 2 s r g 5 8 2 s r g 0 4 6 m 4 2 s r g 0 0 3 s r g 0 8 6 m 5 2 s r g 5 1 3 s r g 0 2 7 LENGTH OF CONNECTIONS TABLE B R22 charge depende...

Страница 19: ...or and connect the sensor wire supplied To configure for COOLING ONLY Remove the RC marked MODEL PLUG and replace with ST marked MODEL PLUG mounted on the electronic circuit board MODEL PLUG SX Split...

Страница 20: ...e AAA LR 03 AMG SET CLR HOUR CONFIGURATION OF REMOTE CONTROL To change the configuration 1 Remove the batteries 2 Set the switches 3 MANDATORILY perform a RESET see below 4 Reinstall the batteries RES...

Страница 21: ...C G X S s e p i p g n i k n i L n o i t c e s e l b a C 3 x 1 5 4 x 1 5 5 2 7 6 8 10 3 x 1 5 4 x 1 5 8 5 12 12 16 3 x 2 5 4 x 1 5 11 9 16 16 16 3 x 2 5 5 x 1 5 16 2 23 5 25 25 3 x 2 5 5 x 1 5 SX12 SX1...

Страница 22: ...SUPPLY TO INDOOR UNIT POWER SUPPLY TO OUTDOOR UNIT WITHOUT ELECTRIC HEATING SX12 16 230V WITHOUT ELECTRIC HEATING 230V 50Hz SX18 24 ELECTRICAL CONNECTIONS SX Split system for wall ceiling mounting MAN...

Страница 23: ...WITHOUT ELECTRIC HEATING POWER SUPPLY TO OUTDOOR UNIT SX30 230V 50Hz WITH WITHOUT ELECTRIC HEATING SX18 24 28 30 3N 400V SX Split system for wall ceiling mounting ELECTRICAL CONNECTIONS MANUAL MENU...

Страница 24: ...POWER Comes on as soon as the unit is energised E PROGRAMMING Comes on during operation Flashes to indicate that the remote control signal has been received and stored in the memory F FILTER Comes on...

Страница 25: ...filter indicator light F goes out Do not operate the air conditioner without the filter Cleaning of the air conditioner Rub the inside of the unit with a soft dry cloth Do not use hot water or volati...

Страница 26: ...is not damaged by impacts or scratches and clean with an appropriate tool if necessary Electrical section Check that the main power supply cable is not damaged or altered in such a way as to affect t...

Страница 27: ...THE INDOOR LIQUID TUBE DURING INSTALLATION WITHOUT THIS KIT THE UNIT WILL NOT OPERATE PROPERLY IN THE HEATING MODE See BELOW FIGURE 1 2 3 4 Fig 1 LIQUID TUBE 2 SUCTION TUBE 3 RESTRICTOR 4 INDOOR UNIT...

Страница 28: ...MANUAL MENU...

Страница 29: ...MANUAL MENU...

Страница 30: ...MANUAL MENU...

Страница 31: ...MANUAL MENU...

Страница 32: ...MANUAL MENU...

Страница 33: ...fices on the parkSuite 27 8 Greenhill Road Wayville SA 5034 TEL 08 8372 7866 FAX 08 8372 7816 PERTH Suite 23 350 Cambridge St Wembley WA 6014 TEL 08 9284 0800 FAX 08 9284 0600 NEWCASTLE Suite 3 19 Dar...

Отзывы: