In the case of a ceiling mounted installation
run the evacuation tube down along the
side panel and secure it with clamps as
shown below. Also break the preformed
cut out in the corner of the intake grid.
Tappo
Recipiente di recupero delle condense
Tubo di scarico
Tubo LIQUIDO
LIQUID tube
Tubo GAS
CONNECTION OF CONDENSATE
EVACUATION TUBE
-
Water condensation must be evacuated
directly to the outside; observe an
appropriate slope for the evacuation duct,
which should slope downwards in the case
of a connection to the wastewater system
(2.5 cm/m slope).
- An S-bend must be installed on the
evacuation duct, below the level of the
recovery tray of the unit.
-
Provide insulation for the evacuation tube
in the case of a risk of freezing or condensation.
- Evacuation with pump kit: (refer to
tions provided with kit).
- The unit is supplied with an evacuation tube
- The right and left outlets are blocked off by
a plug.
Do not forget to remove this plug
before connecting the evacuation tube.
Tapón
Bandeja de recuperación de condensados
Tubo de evacuación
Tubo de LÍQUIDO
Tubo de GAS
GAS tube
Evacuation tube
Plug
-
Condensate recovery tray
SX
Split system for wall / ceiling mounting