background image

 

 

 

 

 

 

ECP (Australia) Pty Ltd. 

 

 

 
 
 
 
 
 

ECP (Australia) Pty Ltd 

HEAD OFFICE 

745 Springvale Road 

Tel (03) 9271 3505 

Fax (03) 9271 3515 

Mulgrave,  3170,  Victoria. 

 

Tech Support Freecall 1800 1800 04. 

Email 

[email protected]

               Website  

www.airwell.com.au

 

 

VICTORIA 

745 Springvale Road 

Tel (03) 9271 3513 

Fax (03) 9271 3540 

Mulgrave,  3170,  Victoria. 

 

NEW SOUTH WALES 
Sydney 

Cnr Marion St & Airport Ave 

Tel (02) 9793 3644 

Fax (02) 9793 3688 

Bankstown Airport,  2200,  NSW. 

Newcastle 

Suite 3, 19 Darby St, 

Tel (02) 4940 4652 

Fax (02) 4940 4653 

Newcastle,  2300,  NSW. 

 

QUEENSLAND 

Unit 9, 123 Muriel Ave 

Tel (07) 3392 8113 

Fax (07) 3392 8115 

Moorooka,  4105,  QLD. 

 

WESTERN AUSTRALIA 

Suite 23, Cambridge Forum 

Tel (08) 9284 0800 

Fax (08) 9284 0600 

350 Cambridge St, Wembley   WA   6014. 

 

SOUTH AUSTRALIA 

Offices on the Park 

Tel (08) 8372 7866 

Fax (08) 8372 7816 

Suite 27,  8 Greenhill Rd, Wayville   SA   5034. 

 

NEW ZEALAND 

517a Rosebank Rd  Tel (09) 

8

20 0333 Fax (09) 820 0332 

Avondale, Auckland NZ 
 
 

ABN 37 082 755 655 Ju

ly

 2003. 

NZ Tech Support Freecall

 

             

Tel 0

800

 

180

 

094

Содержание K CassetteSeries

Страница 1: ...RAC Controller Service Installation Manual DS Series Ducted XLM17 36 Series Wall Split XLS Series Wall Split K Series Cassette SX Series Console AIR CONDITIONING 23 07 03...

Страница 2: ...tting the Remote 15 7 Onboard LED display Onboard switches 16 Mode Reset Switch 17 Remote Clock Terminals 17 8 Self Diagnostic Operation Red Flashing LED 18 Self Diagnostic Table 19 9 Thermistor Resis...

Страница 3: ...work system including entering and leaving weatherproof louvres if fitted must be negligible pressure loss 3 8 In addition to the service clearances noted on the dimension sheet it is essential that p...

Страница 4: ...unit avoiding hot surfaces such as hot water pipes boiler flues etc 8 2 The refrigerant piping should be as short and straight as possible to obtain the most efficient performance 8 3 All vertical ga...

Страница 5: ...at switchboard using circuit breakers Low Voltage wiring including sensor wire must be wired using shielded cable and must not be run in conduits with power wiring 240 415 volt as any induced voltage...

Страница 6: ...diagram Procedure 1 Select minimum acceptable wire size to handle starting current graph 1 2 Check that wire size from step 1 is adequate for full load current increase size as necessary graph 2 3 Che...

Страница 7: ...utdoor coil defrost sensor 240 Volt supply Power Supply to Indoor Unit E Earth 4 Cores Earth two core sensor wires indoor to outdoor Keep Low Voltage Sensor 5Volt Cable Separate 100mm away from the Po...

Страница 8: ...oil defrost sensor 240 Volt supply E Earth L N Active Outdoor Unit Indoor Unit Power Supply to Outdoor Unit 5 Cores Earth two core sensor wires indoor to outdoor Large Single Phase Units 7kW use 4mm2...

Страница 9: ...0 v A 240 v A 240 v N 5 volt 5 volt Outdoor coil defrost sensor Power Supply to Outdoor Unit N E L1 L2 415 Volt supply L3 E 1 Earth Supply active 240v 5 Cores Earth two core sensor wires indoor to out...

Страница 10: ...ive RV Active Fan Active Power Supply to Outdoor Unit N L E 240 Volt supply 1 E 3 4 5 6 1 E 3 4 5 6 8 9 8 9 Earth Active 1 E 3 4 5 6 No need to wire the outdoor sensor wires Remove 3 Pin Power plugs f...

Страница 11: ...RCC 3 8 5 8 25 10 m INDOOR 2 5mm 15a FIVE 1 PAIR SX GC24RCC 3 8 5 8 25 10 m OUTDOOR 2 5mm 20a SIX 1 PAIR SX GC30RCF 3 8 5 8 25 10 m OUTDOOR 4 0mm 25a SIX 1 PAIR HI WALL XLM GCXLM9RCA 1 4 3 8 10 6 m IN...

Страница 12: ...s pumping it is operating correctly If it is noisy and not pumping it is running the wrong direction and will fail within minutes Reverse two of the phases to correct the running direction of the comp...

Страница 13: ...ves or papers over a period of time The surface should be inspected periodically and cleaned down by hosing or steam cleaning as required 5 ELECTRICAL The contact surfaces of relays and contactors sho...

Страница 14: ...RC4 REMOTE CONTROL Page 12...

Страница 15: ...RC4 MODES OF OPERATION FUNCTIONS FEATURES Page 13...

Страница 16: ...Page 14...

Страница 17: ...L FAN DRY ACTIVE ON ON AUTO FAN OFF NO HORIZONTAL SWING RC4 only ON HORIZONTAL SWING ON RC4 only OFF BACK LIGHT OFF RC4 only ON BACK LIGHT ON RC4 only Resetting the remote controller To reset the remo...

Страница 18: ...ter Light Filter Lights up when the air filter needs cleaning E Cooling Light Cool Lights up when the F Mode Button is pushed Manual Cool Operation F Operating mode button Cooling Heating operation Us...

Страница 19: ...again CLK TERMINALS Located on the PCB Using the CLK terminals the unit can be turned ON and OFF remotely via a time clock remote switch or motion sensor The contacts must be voltage free and shielde...

Страница 20: ...on the wall receiver of the ducted units You will hear 3 short beeps and the lighting of the Cool and Heat green and red LED s The unit is now in self diagnosis mode If you do not hear 3 beeps then t...

Страница 21: ...cate a problem with the refrigerant charge or another problem with the refrigeration system Outdoor Coil Sensor and Indoor Coil Sensor temperature readings do not change Check the compressor operation...

Страница 22: ...thermistor This cable is 5 volts DC 5 Volts DC can be induced easily if it is run with power wires between the indoor and outdoor units When the indoor PCB picks up 5 volts it assumes the outdoor coil...

Страница 23: ...0 33069 32179 33907 46 4233 4150 4312 1 31392 30554 32183 47 4074 3995 4150 2 29812 29022 30557 48 3923 3847 3995 3 28322 27577 29025 49 3778 3705 3847 4 26916 26213 27579 50 3639 3570 3705 5 25590 24...

Страница 24: ...6 83 45 1 527 2 75 2 3 744 6 74 46 1 487 3 3 695 6 65 47 1 447 4 3 646 6 56 48 1 409 5 3 595 6 47 49 1 371 6 3 544 6 38 50 1 334 2 4 7 3 492 6 29 51 1 298 8 3 443 6 19 52 1 263 9 3 388 6 09 53 1 228 1...

Страница 25: ...loor Console OFF OFF ON ON WS053 66 XLM17 24 OFF ON OFF ON WS088 100 XLM30 36 OFF ON ON ON STEP 4 Push the On Off button to advance to the next test Test will start immediately watch carefully TEST 2...

Страница 26: ...Timer are ON Fail condition 0 sec Standby is ON 3 sec Standby Operate Timer Filter are ON When the timing reset test is completed after 1 second the next test will start automatically TEST 6 Memory Te...

Страница 27: ...as a separate part Part Numbers DS Ducted units 435726 K Cassette Units 243196 SX Floor Console TBA XLM30 36RCA 435729 If the unit beeps at 3 second Approx intervals and no operation On first start up...

Страница 28: ...J2 J2 is Cooling Only Reverse Cycle Designation J2 Shorted Cooling Only J2 Opened Reverse Cycle WS WMN Wall Split Red Loops J1 J7 J4 DS EMD Ducted Split Purple Loops J1 J7 J4 J3 J8 UA K ECF Cassette S...

Страница 29: ...Stop Low Selected L M H 30o C 35o C 40o C Indoor Coil Temp Indoor Fan Speed Process of Operation Indoor Fan Operation In Heating Mode Page 27...

Страница 30: ...on in Cooling mode Indoor fan goes to low speed at 61o C to reduce the unit s capacity therefore reducing the outdoor coil temperature Compressor cuts out at 64o C outdoor coil high temperature protec...

Страница 31: ...ncreasing Indoor Coil Temperature Compressor Cuts out at 1o C as Indoor Coil Anti freeze Protection This Condition can be Experience if the Unit is Overcharged or Under Normal Operation of Cooling on...

Страница 32: ...Two Types Of Defrost Initiation Static Dynamic Time Or Temp Termination Defrost Interval Time Change to Suit Conditions Process of Operation De Ice Low Outdoor Coil Operation In Heating Mode Page 30...

Страница 33: ...below 40o C providing De Ice interval time is complete OCT Outdoor Coil Temp Process of Operation De Ice De Ice Initiation At 12o C or After 10 Mins De Ice Time Interval The time between de ice is alw...

Страница 34: ...Splitter Receiver Master Controller 5m Cabl Model Particulars Ducted Units Infrared Receivers Options The Ducted Receiver is not a Room Temp Sensor It s a Signal Receiver only 8m Cables 5m Extension C...

Страница 35: ...red See professional web site www airwell com au the pass word or faxed copy is available from tech support on 1800 1800 04 Prompt 4 Multiple Models Multiple Wiring Refer Product Bulletin PB085 Softst...

Страница 36: ...793 3688 Bankstown Airport 2200 NSW Newcastle Suite 3 19 Darby St Tel 02 4940 4652 Fax 02 4940 4653 Newcastle 2300 NSW QUEENSLAND Unit 9 123 Muriel Ave Tel 07 3392 8113 Fax 07 3392 8115 Moorooka 4105...

Отзывы: