ELECTRONIC FUNCTION
JMF Series 38 Version - 1
Auto fan action:
When T1-Ts>2
℃
, the indoor fan will run at low speed.
When T1-Ts
≤0
℃
, the indoor fan will run at medium speed.
9.4.3.4 Defrosting mode
:
Defrosting action
:
For ELSI-JMF024-N11:
Condition of defrosting:
AC will enter defrosting mode if any of the following items is satisfied.
(1) If T3<TC1 and the compressor keeps running over 45 minutes. Meanwhile T3
<
TC3 for
5minutes
(2) After the last defrosting, the time that the outdoor fan is off but the compressor is on in high
T2 protection cumulates up to 90 minutes.
Condition of ending defrosting:
If any one of the following items is satisfied, the defrosting will terminate and the machine will turn
to normal heating mode.
(1) T3 rises to be higher than TC2.
(2) The machine has run for 10 minutes in defrosting.