ELECTRONIC FUNCTION
JMF Series 42 Version - 1
8.4.7.3 Timer off. The machine will turn off automatically when reaching the setting time.
8.4.7.4 Timer on/off. T
he machine will turn on automatically when reaching the setting “on” time,
and then turn off automatically when reaching the setting “off” time.
8.4.7.5 Timer off/on. T
he machine will turn off automatically when reaching the setting “off” time,
and then turn on automatically when reaching the setting “on” time.
8.4.7.6 The timer function will not change the AC current operation mode. Suppose AC is off now,
it will not start up firstly after setting the
“timer off” function. And when reaching the setting time,
the timer LED will be off and the AC running mode has not been changed.
8.4.7.7 The setting time is relative time.
8.4.7.8 The AC will quit the timer function when it has malfunction.
9.4.8 Sleep function mode
8.4.8.1 Operation time in sleep mode is 7 hours. After 7 hours the AC quits this mode and turns
off.
8.4.8.2. Operation process in sleep mode is as follow:
When cooling, the setting temperature rises 1
℃
(be lower than 30
℃
) every one hour, 2 hours
later the setting temperature stops rising and indoor fan is fixed as low speed.
When heating, the setting temperature decreases 1
℃
(be higher than 17
℃
) every one hour, 2
hours later the setting temperature stops rising and indoor fan is fixed as low speed. (Anti-cold
wind function has the priority)
8.4.8.3 Timer setting is available
8.4.8.4 When user uses timer off function in sleep mode (or sleep function in timer off mode), if the
timing is less than 7 hours, sleep function will be cancelled when reaching the setting time. If the
timing is more than 7 hours, the machine will not stop until reaches the setting time in sleep mode.
9.4.9 Auto-Restart function
The indoor unit is equipped with auto-restart function, which is carried out through an auto-restart
module. In case of a sudden power failure, the module memorizes the setting conditions before
the power failure. The unit will resume the previous operation setting (not including swing function)
automatically after 3 minutes when power returns.
If the memorization condition is forced cooling mode, the unit will run in cooling mode for 30
minutes and turn to auto mode as 24
℃
setting temp.
If AC is off before power off and AC is required to start up now, the compressor will have 1 minute
delay when power on. Other conditions, the compressor will have 3 minutes delay when restarts.
9.4.10 Refrigerant Leakage Detection
With this new technology, the display area will show
“EC” when the outdoor unit detects refrigerant
leakage.
9.4.11 Louver Position Memory Function
When starting the unit again after shutting down, its louver will restore to the angle originally set by
the user, but the precondition is that the angle must be within the allowable range, if it exceeds, it
will memorize the maximum angle of the louver. During operation, if the power fails or the end
user shuts down the unit in the turbo mode, the louver will restore to the default angle.
9.4.12 8
℃
Heating
Содержание Electra ELAU-VMF007-H11
Страница 17: ...WIRING DIAGRAM JMF Series 17 Version 1 ELSI JMF024 N11...
Страница 18: ...WIRING DIAGRAM JMF Series 18 Version 1 6 2 Outdoor Unit ELAU JMF007 H11 ELAU JMF009 H11 ELAU JMF012 H11...
Страница 19: ...WIRING DIAGRAM JMF Series 19 Version 1 ELAU JMF018 H11...
Страница 20: ...WIRING DIAGRAM JMF Series 20 Version 1 ELAU JMF024 H11...
Страница 72: ...JMF Series 72 Version 1 SERVICE MANUAL JMF Series...