CHARACTERISTIC OF TEMPERATURE SENSOR 

Window WDF                                    19                               Version - 0          

10 Characteristic of temperature sensor. 

Temp.

 

Resistance K

 

Temp.

Resistance K

Temp.

Resistance K

-10 62.2756 

17  14.6181 

44  4.3874 

-9 58.7079  18 13.918 

45 4.2126 

-8 56.3694  19 13.2631  46 4.0459 

-7 52.2438  20 12.6431  47 3.8867 

-6 49.3161  21 12.0561  48 3.7348 

-5 46.5725  22 11.5 

49 3.5896 

-4 44 

23 10.9731  50 3.451 

-3 41.5878  24 10.4736  51 3.3185 

-2 39.8239  25 10 

52 3.1918 

-1 37.1988  26 9.5507 

53 3.0707 

0 35.2024  27 

9.1245  54 2.959 

1 33.3269  28 

8.7198  55 2.8442 

2 31.5635  29 

8.3357  56 2.7382 

3 29.9058  30 

7.9708  57 2.6368 

4 28.3459  31 

7.6241  58 2.5397 

5 26.8778  32 

7.2946  59 2.4468 

6 25.4954  33 

6.9814  60 2.3577 

7 24.1932  34 

6.6835  61 2.2725 

8 22.5662  35 

6.4002  62 2.1907 

9 21.8094  36 

6.1306  63 2.1124 

10 20.7184  37 5.8736 

64 2.0373 

11 19.6891  38 5.6296 

65 1.9653 

12 18.7177  39 5.3969 

66 1.8963 

13 17.8005  40 5.1752 

67 1.830 

14 16.9341  41 4.9639 

68 1.7665 

15 16.1156  42 4.7625 

69 1.7055 

16 15.3418  43 4.5705 

70 1.6469 

                                                                           

Содержание AWWR-WDF009-C11

Страница 1: ...PRECAUTION Window WDF Series Models AWWR WDF009 C11 AWWR WDF012 C11...

Страница 2: ...utes delay at restart for compressor 12 7 2 2Anti freezing protection at cooling or dry mode 12 7 2 3 Anti frosting protection and defect at cooling or dry mode 12 7 2 4 Electronic function 13 7 3 Tem...

Страница 3: ...isassemble or repair the product there is risk of fire or electric shock z Always ground the product There is risk of fire or electric shock z Install the panel and the cover of control box securely T...

Страница 4: ...z Do not place anything on the power cable There is risk of fire or electric shock z Do not plug or unplug the power supply plug during operation There is risk of fire or electric shock z Do not touc...

Страница 5: ...n operating it together with a stove etc There is risk of fire or electric shock z Turn the main power off when cleaning or maintaining the product There is risk of electric shock z When the product i...

Страница 6: ...is risk of fire electric shock or damage to the plastic parts of the product z Do not touch the metal parts of the product when removing the air filter They are very sharp There is risk of personal i...

Страница 7: ...mble the batteries Do not dispose of batteries in a fire They may burn of explode z If the liquid from the batteries gets onto your skin or clothes wash it well with clean water Do not use the remote...

Страница 8: ...80 350 310 490 450 400 External static pressure Min Max Pa 0 0 Sound power level 4 H M L dB A 56 57 Sound pressure level 5 H M L dB A 49 47 45 49 47 45 Moisture removal l hr 1 1 2 Condensate drain tub...

Страница 9: ...DIMENSION Window WDF 7 Version 0 3 Dimension...

Страница 10: ...control in cooling mode or drying mode Prevent the water being freezed on evaporator by sensing the evaporator pipe temperature in cooling mode Time Delay Safety Restarting is for approx 3 minutes Au...

Страница 11: ...op timer function Auto Start Stop programs can be from 0 12 hours Each depression of the TIMER keypad will increase the selected time in 1 hour increments 4 FAN SPEED BUTTON Press the button to select...

Страница 12: ...important components and their function in what is called the refrigeration system This will help to understand the refrigeration cycle and the flow of the refrigerant in the cooling cycle F o r o n l...

Страница 13: ...WIRING DIAGRAM Window WDF 11 Version 0 6 Wiring Diagram...

Страница 14: ...r will stay off Otherwise the compressor will be started and the function is cancelled Anti freezing control according to TIME If the lasting time of compressor which is continuously running has got t...

Страница 15: ...nit or the remote controller 7 2 4 Electronic function 7 2 4 1 Cooling mode The speed of indoor fan can be optionally chosen as High Mid optional Low Compressor running rules T1 TS 2 F compressor on T...

Страница 16: ...T or T 4 the machine will choose actual running mode again according to T1 Ts till the compressor stops 7 2 4 3 Fan mode 1 Compressor stops 2 Temperature setting function is disabled 3 The speed of i...

Страница 17: ...obstacle such as a fence or wall within 500mm from the back of the ambient because it will prevent heat radiation of the condenser 4 Restriction of outside air will greatly reduce the cooling and hea...

Страница 18: ...ed securely Avoid placing furniture of draperies in front of the air inlet and outlet 8 3 How to drain To get the maximum cooling efficiency the air conditioner is designed to splash the condensation...

Страница 19: ...he enlargement of noise or vibration 3 Fill up sews in the cabinet with sponge or foam z Use iron support The installation hole should be strong enough to support the air conditioner If it cannot iron...

Страница 20: ...INSTALLATIOIN Window WDF 18 Version 0...

Страница 21: ...6 51 3 3185 2 39 8239 25 10 52 3 1918 1 37 1988 26 9 5507 53 3 0707 0 35 2024 27 9 1245 54 2 959 1 33 3269 28 8 7198 55 2 8442 2 31 5635 29 8 3357 56 2 7382 3 29 9058 30 7 9708 57 2 6368 4 28 3459 31...

Страница 22: ...the other is called the Structure Damage Operation panel don t work Check the power supply Press the LED button of remote controller several times and check whether the problem is settled down Check t...

Страница 23: ...r con doesn t work Check the power supply Check whether the transformer is failed Measure the output voltage of transformer and check whether it is the range from 5V to 12V If not replace the transfor...

Страница 24: ...blocked Check whether the indoor ambient temperature is too low Check whether the indoor dust filter is too dirty Check whether there is too much water on the chassis No No No No No No Check the pipe...

Страница 25: ...the wiring Check whether the compressor is under overload protection No No No No No No Check whether the external protector works noamally Remove the overload protector and cool to normal temperature...

Страница 26: ...ng mode check whether the temperature of the compressor s discharge pipe is smaller than 90 if no recharge refrigerant Replace the capillary No No No No The air con doesn t work Check the power supply...

Страница 27: ...airflow passage is blocked Check whether the fan motor doesn t work Check whether capacitor of compressor work normally Check whether the relay of compressor on PCB works normally Replace the PCB Che...

Страница 28: ...Check whether the indoor outlet airflow foam is too wet and louver drip Check whether the unit is correctly installed Check whether the air outlet foam install normally No No No No Check whether the...

Страница 29: ...rd Replace the compressor Replace the main PCB No voltage Check whether the indoor outlet inlet of the unit is blocked or the vent is blocked Check whether the Evap is frosting and the compressor stop...

Страница 30: ...EXPLODED VIEW AND PART LIST Window WDF 28 Version 0 12 Exploded view and part list AWWR WDF009 C11...

Страница 31: ...ver of control panel 20 Discharge pipe assembly 7 Cover of electronic control box 21 Condenser assembly 8 Electronic control box assembly 22 Centrifugal fan 8 1 Electronic control box 23 Volute shell...

Страница 32: ...EXPLODED VIEW AND PART LIST Window WDF 30 Version 0 AWWR WDF012 C11...

Страница 33: ...oor 22 Volute shell below 8 Electronic control box assembly 23 Ventilation ring 8 1 Electronic control box 24 Evaporator coil assembly 8 2 Capacitor of compressor 26 Compressor 8 3 Capacitor of fan mo...

Страница 34: ......

Страница 35: ...Window WDF 1 Version 0 SERVICE MANUAL Window WDF Series...

Отзывы: